pressure data recorded from downhole transducers<br />

during the pumping and recovery portions <strong>of</strong> this test<br />

are reported in HydroGeoChem (1985).<br />

The fluid-pressure responses <strong>of</strong> DOE-1 during the<br />

drawdown and recovery periods were very different.<br />

The shape <strong>of</strong> the drawdown-data curve on a log-log<br />

plot (Figure 5-76) is indicative <strong>of</strong> a well intersecting a<br />

single, high-conductivity fracture, with multiple n<strong>of</strong>low<br />

boundary effects evident at late time. The loglog<br />

plot <strong>of</strong> the recovery data (Figure 5-77), on the<br />

other hand, shows a clear double-porosity response<br />

with no indications <strong>of</strong> hydraulic boundaries.<br />

The log-log drawdown plot (Figure 5-76) includes a<br />

simulation generated by INTERPRET for a well<br />

intersected by a single high-conductivity fracture.<br />

The transmissivity <strong>of</strong> the Culebra apart from the<br />

fracture is 28 ft*/day (Table 5-3) for this simulation.<br />

Assuming a porosity <strong>of</strong> 20%, a total-system<br />

compressibility <strong>of</strong> 1 .O x 10-5 psi-‘, and a fluid viscosity<br />

<strong>of</strong> 1.0 cp, the skin factor for this simulation is -5.1, a<br />

reasonable value for a well intersecting a fracture.<br />

The data match the simulation reasonably well for the<br />

first 13.5 hr, but then, starting with a discrete<br />

pressure drop caused by increasing the pumping<br />

rate from 9.1 to 10.3 gpm (HydroGeoChem, 1985)’<br />

the data deviate above the simulation. This type <strong>of</strong><br />

deviation is usually indicative <strong>of</strong> no-flow (or lower<br />

permeability) hydraulic boundaries. In this case,<br />

multiple boundaries are indicated by the amount <strong>of</strong><br />

deviation from the simulation.<br />

102<br />

I I I I<br />

n<br />

ui<br />

5 10’<br />

m<br />

w<br />

K<br />

n<br />

m<br />

m<br />

W<br />

-I<br />

z<br />

0<br />

m<br />

2 100<br />

w<br />

E<br />

n<br />

MATCH PARAMETERS<br />

Ap = 1.0 psi<br />

t<br />

= 1.0 hr<br />

pD = 0.21<br />

tD/CD = 173<br />

CDeZs 7.64 x<br />

n PRESSURE DATA<br />

3i PRESSURE-DERIVATIVE DATA<br />

- SIMULATIONS<br />

%P<br />

*<br />

10-’10c<br />

Y<br />

* I I I I<br />

10’ 102 103 104 105<br />

Figure 5-76. DOE-11Culebra Pumping Test Drawdown Log-Log Plot with INTERPRET Simulation<br />