Beauheim 1987 - Waste Isolation Pilot Plant - U.S. Department of ...
Beauheim 1987 - Waste Isolation Pilot Plant - U.S. Department of ...
Beauheim 1987 - Waste Isolation Pilot Plant - U.S. Department of ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
5.2.2.21 below) and DOE-2 (<strong>Beauheim</strong>, 1986). Those<br />
wells exhibited restricted interporosity flow, with<br />
delayed transition between flow from the fractures<br />
only and flow from the fractures and matrix<br />
combined, and less negative skin factors (-6.0 and<br />
-4.7). The cause(s) <strong>of</strong> these differences in behavior<br />
is not understood at the present time.<br />
Because the Poker Trap well did not respond to the<br />
pumping at H-8b (INTERA Technologies, 1986), no<br />
storativity value for the Culebra was obtainable from<br />
the test. The failure <strong>of</strong> either the Magenta in H-8a or<br />
the Rustler-Salado contact in H-8c to respond to the<br />
Culebra pumping at H-8b indicates that any existing<br />
communication between the Culebra and those units<br />
is <strong>of</strong> a degree too low to allow observable responses<br />
on the time scale <strong>of</strong> this test.<br />
5.2.2.4 H-12. Although H-12 was completed in<br />
1983, no well-controlled hydrologic testing <strong>of</strong> the<br />
Culebra had ever been performed. Pressure data<br />
were collected during a water-quality sampling<br />
exercise in 1984 (INTERA and HydroGeoChem,<br />
1985), but the data were inadequate for interpretation<br />
and provided only a qualitative indication <strong>of</strong> low<br />
transmissivity. Thus, two falling-head slug tests were<br />
performed in August and September <strong>1987</strong> to provide<br />
estimates <strong>of</strong> the Culebra transmissivity at H-12.<br />
The first test was initiated on August 27, <strong>1987</strong>, and<br />
the second test on September 1, <strong>1987</strong>. The data<br />
from these tests are presented in Stensrud et al.<br />
(1988). Complete recovery from the induced<br />
pressure differential was obtained during each test.<br />
Figure 5-24 shows a semilog plot <strong>of</strong> the data from the<br />
first test, along with the best-fit type-curve match.<br />
This match provides a transmissivity estimate <strong>of</strong><br />
0.18 ftzlday (Table 5-3). The same type-curve match<br />
also fits the data from the second test quite well<br />
(Figure 5-25), resulting in an identical transmissivity<br />
estimate.<br />
Figure 5-24. H-l2/Culebra Slug-Test #1 Plot<br />
66