5.2.2.21 below) and DOE-2 (<strong>Beauheim</strong>, 1986). Those<br />

wells exhibited restricted interporosity flow, with<br />

delayed transition between flow from the fractures<br />

only and flow from the fractures and matrix<br />

combined, and less negative skin factors (-6.0 and<br />

-4.7). The cause(s) <strong>of</strong> these differences in behavior<br />

is not understood at the present time.<br />

Because the Poker Trap well did not respond to the<br />

pumping at H-8b (INTERA Technologies, 1986), no<br />

storativity value for the Culebra was obtainable from<br />

the test. The failure <strong>of</strong> either the Magenta in H-8a or<br />

the Rustler-Salado contact in H-8c to respond to the<br />

Culebra pumping at H-8b indicates that any existing<br />

communication between the Culebra and those units<br />

is <strong>of</strong> a degree too low to allow observable responses<br />

on the time scale <strong>of</strong> this test.<br />

5.2.2.4 H-12. Although H-12 was completed in<br />

1983, no well-controlled hydrologic testing <strong>of</strong> the<br />

Culebra had ever been performed. Pressure data<br />

were collected during a water-quality sampling<br />

exercise in 1984 (INTERA and HydroGeoChem,<br />

1985), but the data were inadequate for interpretation<br />

and provided only a qualitative indication <strong>of</strong> low<br />

transmissivity. Thus, two falling-head slug tests were<br />

performed in August and September <strong>1987</strong> to provide<br />

estimates <strong>of</strong> the Culebra transmissivity at H-12.<br />

The first test was initiated on August 27, <strong>1987</strong>, and<br />

the second test on September 1, <strong>1987</strong>. The data<br />

from these tests are presented in Stensrud et al.<br />

(1988). Complete recovery from the induced<br />

pressure differential was obtained during each test.<br />

Figure 5-24 shows a semilog plot <strong>of</strong> the data from the<br />

first test, along with the best-fit type-curve match.<br />

This match provides a transmissivity estimate <strong>of</strong><br />

0.18 ftzlday (Table 5-3). The same type-curve match<br />

also fits the data from the second test quite well<br />

(Figure 5-25), resulting in an identical transmissivity<br />

estimate.<br />

Figure 5-24. H-l2/Culebra Slug-Test #1 Plot<br />