Type 2 Surge Arresters for Use in PV Systems<br />

DEHNguard ® modular (Y)PV SCI ... (FM)<br />

DEHNguard M YPV SCI ... FM<br />

DC+/-<br />

DC-/+<br />

30<br />

DC+/– 9 DC–/+<br />

90<br />

45<br />

12<br />

11<br />

14<br />

15.3<br />

54 7<br />

(3 mods.)<br />

9<br />

43.5<br />

66<br />

11<br />

952 518<br />

DG M YPV SCI 150 FM<br />

952 516<br />

DG M YPV SCI 600 FM<br />

952 515<br />

DG M YPV SCI 1000 FM<br />

DG 952 M 517 YPV SCI 150 FM<br />

952 DG M 518 YPV SCI 1200 FM<br />

Überspannungsableiter Typ 2 DEHNguard M Mehrpolig für PV-Anlagen<br />

bis 150V DC<br />

DG M YPV SCI 600 FM<br />

952 516<br />

Überspannungsableiter Typ 2 DEHNguard M<br />

Mehrpolig<br />

für PV-Anlagen bis 600V DC<br />

DG M YPV SCI 1000 FM<br />

952 515<br />

Überspannungsableiter Typ 2 DEHNguard M<br />

Mehrpolig<br />

für PV-Anlagen bis 1000V DC<br />

DG M YPV SCI 1200 FM<br />

952 517<br />

Überspannungsableiter Typ 2 DEHNguard M<br />

Mehrpolig<br />

für PV-Anlagen bis 1200V DC<br />

Dimension drawing DG M YPV SCI ... FM<br />

Basic circuit diagram DG M YPV SCI ... FM<br />

Modular multipole surge arrester with three-step d.c. switching device for use in PV systems with<br />

remote signalling contact for monitoring device (floating changeover contact)<br />

• Prewired modular complete unit for use<br />

in photovoltaic systems consisting of a<br />

base part and plug-in protection modules<br />

• Combined disconnection and short-circuiting<br />

device with safe electrical isolation<br />

in the protection module prevents<br />

fire damage caused by d.c. switching<br />

arcs (patented SCI principle)<br />

• Safe replacement of protection modules<br />

without arc formation due to integrated<br />

d.c. fuse<br />

Type DG M YPV SCI 150 FM DG M YPV SCI 600 FM DG M YPV SCI 1000 FM DG M YPV SCI 1200 FM<br />

Part No. 952 518 + 952 516 952 515 952 517<br />

Conformity with prEN 50539-11 yes yes yes yes<br />

SPD classification according to EN 61643-11 Type 2 Type 2 Type 2 Type 2<br />

SPD classification according to IEC 61643-1/-11 Class II Class II Class II Class II<br />

Max. PV voltage (U CPV ) ≤ 150 V ≤ 600 V ≤ 1000 V ≤ 1200 V<br />

Short-circuit withstand capacity (I SCWPV ) 1000 A 1000 A 1000 A 1000 A<br />

Max. continuous operating d.c. voltage [(DC+/DC-) --> PE] (U C ) 75 V 300 V 500 V 600 V<br />

Total discharge current (8/20 μs) (I total ) 40 kA 40 kA 40 kA 30 kA<br />

Nominal discharge current (8/20 μs) [(DC+/DC-) --> PE] (I n ) 10 kA 12.5 kA 12.5 kA 12.5 kA<br />

Max. discharge current (8/20 μs) [(DC+/DC-) --> PE] (I max ) 20 kA 25 kA 25 kA 25 kA<br />

Voltage protection level (U P ) ≤ 0.8 kV ≤ 2.5 kV ≤ 4 kV ≤ 4.5 kV<br />

Voltage protection level at 5 kA (U P ) ≤ 0.6 kV ≤ 2 kV ≤ 3.5 kV ≤ 4 kV<br />

Response time (t A ) ≤ 25 ns ≤ 25 ns ≤ 25 ns ≤ 25 ns<br />

Operating temperature range (T U ) -40°C...+80°C -40°C...+80°C -40°C...+80°C -40°C...+80°C<br />

Operating state/fault indication green / red green / red green / red green / red<br />

Number of ports 1 1 1 1<br />

Cross-sectional area (min.)<br />

1.5 mm 2 solid/flexible<br />

Cross-sectional area (max.)<br />

35 mm 2 stranded/25 mm 2 flexible<br />

For mounting on 35 mm DIN rail acc. to EN 60715<br />

Enclosure material thermoplastic, red, UL 94 V-0<br />

Place of installation indoor installation indoor installation indoor installation indoor installation<br />

Degree of protection IP 20 IP 20 IP 20 IP 20<br />

Capacity 3 modules, DIN 43880 3 modules, DIN 43880 3 modules, DIN 43880 3 modules, DIN 43880<br />

Approvals UL UL, CSA UL, CSA UL<br />

Type of remote signalling contact changeover contact changeover contact changeover contact changeover contact<br />

a.c. switching capacity 250 V/0.5 A 250 V/0.5 A 250 V/0.5 A 250 V/0.5 A<br />

d.c. switching capacity<br />

250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A<br />

Cross-sectional area for remote signalling terminals<br />

max. 1.5 mm 2 solid/flexible<br />

Surge Arresters Type 2<br />

Accessory for DEHNguard ® modular (Y)PV SCI ... (FM)<br />

Varistor-Based Protection Module for<br />

DEHNguard M (Y)PV SCI<br />

Varistor-based protection module for DEHNguard M YPV<br />

SCI ... and DEHNguard S PV SCI ... arresters<br />

Type DG MOD PV ... 75 300 500 600<br />

Part No. 952 045 952 043 952 041 952 044<br />

Max. continuous operating<br />

d.c. voltage (U C ) 75 V 300 V 500 V 600 V<br />

Accessory for DEHNguard ® modular (Y)PV SCI ... (FM)<br />

Varistor-Based Protection Module for<br />

DEHNguard M (Y)PV SCI<br />

Protection module for DEHNguard M (Y)PV SCI ...<br />

arresters comprising a varistor connected in parallel with<br />

a short-circuiting device with integrated back-up fuse<br />

Type DG MOD PV ... SCI 75 SCI 300 SCI 500 SCI 600<br />

Part No. 952 055 952 053 952 051 952 054<br />

Max. continuous operating<br />

d.c. voltage (U C ) 75 V 300 V 500 V 600 V<br />

www.dehn.de<br />