Coordinated Type 1 Lightning Current Arresters<br />

DEHNbloc ® M<br />

DEHNbloc M 1 ... FM<br />

30<br />

L/N<br />

L/N<br />

L'/N'<br />

90<br />

N/PE(N)<br />

36 7<br />

(2 mods.)<br />

43.5<br />

66<br />

45<br />

12<br />

11<br />

14<br />

9<br />

11<br />

15.3<br />

N/PE(N)<br />

961 115<br />

DB M 1 150 FM<br />

961 125<br />

DB M 1 255 FM<br />

961 135<br />

DB M 1 320 FM<br />

DB M 1 150 FM<br />

961 115<br />

Koordinierter Blitzstromableiter Typ 1 DEHNbloc M mit hoher<br />

Folgestrombegrenzung<br />

DB M 1 255 FM<br />

961 125<br />

Koordinierter Blitzstromableiter Typ 1 DEHNbloc M mit hoher<br />

Folgestrombegrenzung<br />

DB M 1 320 FM<br />

961 135<br />

Koordinierter Blitzstromableiter Typ 1 DEHNbloc M mit hoher<br />

Folgestrombegrenzun<br />

Dimension drawing DB M 1 ... FM<br />

Basic circuit diagram DB M 1 ... FM<br />

Coordinated modular single-pole lightning current arrester with high follow current limitation; with<br />

remote signalling contact for monitoring system (floating changeover contact)<br />

• Coordinated spark-gap-based lightning<br />

current arrester consisting of a base<br />

part and plug-in protection module<br />

• Maximum system availability due to<br />

RADAX Flow follow current limitation<br />

• Directly coordinated with DEHNguard<br />

surge protective devices without additional<br />

cable length<br />

Type DB M 1 150 FM DB M 1 255 FM DB M 1 320 FM<br />

Part No. 961 115 961 125 961 135<br />

SPD according to EN 61643-11 Type 1 Type 1 Type 1<br />

SPD according to IEC 61643-1/-11 Class I Class I Class I<br />

Max. continuous operating a.c. voltage (U C ) 150 V 255 V 320 V<br />

Lightning impulse current (10/350 μs) (I imp ) 35 kA 50 kA 25 kA<br />

Specific energy (W/R) 306.25 kJ/ohms 625.00 kJ/ohms 156.25 kJ/ohms<br />

Nominal discharge current (8/20 μs) (I n ) 35 kA 50 kA 25 kA<br />

Voltage protection level (U P ) ≤ 1.5 kV ≤ 2.5 kV ≤ 2.5 kV<br />

Follow current extinguishing capability a.c. (I fi ) 50 kA rms 50 kA rms 50 kA rms<br />

Follow current limitation/Selectivity<br />

no tripping of a 32 A gL/gG fuse up to 50 kA rms (prosp.)<br />

Response time (t A ) ≤ 100 ns ≤ 100 ns ≤ 100 ns<br />

Max. backup fuse (L) up to I K = 50 kA rms (t a ≤ 0.2 s) 500 A gL/gG 500 A gL/gG 315 A gL/gG<br />

Max. backup fuse (L) up to I K = 50 kA rms (t a ≤ 5 s) 315 A gL/gG 315 A gL/gG 315 A gL/gG<br />

Max. backup fuse (L) for I K > 50 kA rms 200 A gL/gG 200 A gL/gG 200 A gL/gG<br />

Max. backup fuse (L-L') 125 A gL/gG 125 A gL/gG 125 A gL/gG<br />

Temporary overvoltage (TOV) (U T ) 200 V / 5 sec. 440 V / 5 sec. 440 V / 5 sec.<br />

TOV characteristics withstand withstand withstand<br />

Operating temperature range (parallel connection) (T UP ) -40°C...+80°C -40°C...+80°C -40°C...+80°C<br />

Operating temperature range (series connection) (T US ) -40°C...+60°C -40°C...+60°C -40°C...+60°C<br />

Operating state/fault indication green / red green / red green / red<br />

Number of ports 1 1 1<br />

Cross-sectional area (L/N, L'/N', N/PE (N)) (min.) 10 mm 2 solid/flexible 10 mm 2 solid/flexible 10 mm 2 solid/flexible<br />

Cross-sectional area (L/N, N/PE(N)) (max.) 50 mm 2 stranded/35 mm 2 flexible 50 mm 2 stranded/35 mm 2 flexible 50 mm 2 stranded/35 mm 2 flexible<br />

Cross-sectional area (L'/N') (max.) 35 mm 2 stranded/25 mm 2 flexible 35 mm 2 stranded/25 mm 2 flexible 35 mm 2 stranded/25 mm 2 flexible<br />

For mounting on 35 mm DIN rail acc. to EN 60715 35 mm DIN rail acc. to EN 60715 35 mm DIN rail acc. to EN 60715<br />

Enclosure material thermoplastic, red, UL 94 V-0 thermoplastic, red, UL 94 V-0 thermoplastic, red, UL 94 V-0<br />

Place of installation indoor installation indoor installation indoor installation<br />

Degree of protection IP 20 IP 20 IP 20<br />

Capacity 2 modules, DIN 43880 2 modules, DIN 43880 2 modules, DIN 43880<br />

Approvals UL, CSA VDE, KEMA, UL UL, CSA<br />

Type of remote signalling contact changeover contact changeover contact changeover contact<br />

a.c. switching capacity 250 V/0.5 A 250 V/0.5 A 250 V/0.5 A<br />

d.c. switching capacity<br />

250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A<br />

Cross-sectional area for remote signalling terminals max. 1.5 mm 2 solid/flexible max. 1.5 mm 2 solid/flexible max. 1.5 mm 2 solid/flexible<br />

Lightn. Curr. Arr. Type 1<br />

Accessory for DEHNbloc ® M<br />

DB M Spark-Gap-Based Protection Module<br />

Spark-gap-based protection module<br />

Type DB M MOD ... 150 255 320<br />

Part No. 961 001 961 002 961 003<br />

Max. continuous<br />

operating a.c. voltage (U C ) 150 V 255 V 320 V<br />

www.dehn.de<br />