07.11.2014 Views

New Products

New Products

New Products

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Easy Choice<br />

L1 L2 L3 N PE<br />

Cable length ≥ 5 m<br />

32 A<br />

RCD<br />

3 A 1<br />

99/ IN<br />

DEHN SPD<br />

SPS PRO<br />

Arrangement I Arrangement II Arrangement III<br />

SPD Type 3<br />

(Surge arrester)<br />

function<br />

OUT / FM<br />

SPS<br />

25 A also<br />

permissible<br />

without NF 10<br />

10 A 1<br />

SPD Type 3<br />

(Surge arrester)<br />

4<br />

2<br />

9<br />

DR M 2P 255 FM<br />

9<br />

DEHNrail<br />

3<br />

1<br />

L L 99 N N<br />

IN<br />

NETZFILTER<br />

OUT<br />

L’ L’ 99 N’ N’<br />

L1 L2 L3 N 9<br />

DEHNrail<br />

DR M 4P 255 FM<br />

L1 L2 L3 N 9<br />

1 x SPS PRO Part No. 912 253 1 x DR M 2P 255 FM Part No. 953 205 1 x DR M 4P 255 FM Part No. 953 405<br />

1 x NF 10 Part No. 912 254 alt. 1 x DR M 4P 255 Part No. 953 400<br />

SPS<br />

fault indication<br />

25 A 1<br />

SPD Type 3<br />

(Surge arrester)<br />

electronic<br />

equipment<br />

Switchgear / Machine<br />

125 A 1<br />

125 A 1<br />

DEHNguard<br />

L1<br />

DG MOD 275<br />

DEHNguard<br />

L2<br />

DG MOD 275<br />

1 x DG M TT 275 Part No. 952 310<br />

DEHNguard<br />

L3<br />

DG MOD 275<br />

9<br />

SPD Type 2<br />

(Surge arrester)<br />

SPD Type 1<br />

(Lightning current arrester)<br />

315 A 1<br />

L/N<br />

Cable length ≥ 15 m<br />

DEHNbloc<br />

DB H MOD 255<br />

N/PE(N)<br />

L/N<br />

DEHNbloc<br />

DB H MOD 255<br />

N/PE(N)<br />

L/N<br />

DEHNguard<br />

DEHNbloc<br />

N<br />

PE<br />

DB H MOD 255<br />

DG MOD NPE<br />

N/PE(N)<br />

PE<br />

DEHNgap<br />

9<br />

N<br />

DGPH MOD 255<br />

315 A 1<br />

L/N<br />

DEHNbloc<br />

DB M 1 255 FM<br />

N/PE(N)<br />

DEHNguard<br />

L1<br />

L/N<br />

DG MOD 275<br />

DEHNguard<br />

DEHNbloc<br />

L2<br />

DG MOD 275<br />

with remote signalling contact:<br />

1 x DG M TT 275 FM Part No. 952 315<br />

DB M 1 255 FM<br />

N/PE(N)<br />

DEHNguard<br />

L3<br />

DG MOD 275<br />

9<br />

SPD Type 2<br />

(Surge arrester)<br />

L/N<br />

DEHNguard<br />

DEHNbloc<br />

N<br />

PE<br />

DG MOD NPE<br />

DB M 1 255 FM<br />

N/PE(N)<br />

PE<br />

fault indication<br />

DEHNbloc ® M<br />

Coordinated with DEHNguard ®<br />

without additional cable length.<br />

SPD Type 1<br />

(Coordinated lightning<br />

current arrester)<br />

DEHNgap<br />

9<br />

N<br />

DGP M 255 FM<br />

fault indication<br />

SPD Type 1<br />

(Combined lightning current<br />

and surge arrester)<br />

315 A 1<br />

DEHNventil ®<br />

Directly coordinated with<br />

Red/Line SPDs Type 2 and 3<br />

without additional cable length.<br />

For serial connection please see also page 18<br />

L1 L1‘ L2 L2‘<br />

DEHNventil<br />

DV MOD 255<br />

DEHNventil<br />

DV MOD 255<br />

L3 L3‘ N<br />

DEHNventil<br />

DV MOD 255<br />

9<br />

DEHNventil<br />

N‘<br />

PE<br />

DV MOD NPE 50<br />

Main Distribution Board Sub-distribution Board<br />

MEB<br />

3 x DBH M 1 255 Part No. 961 122<br />

1 x DGPH M 255 Part No. 961 102<br />

1 x MVS 1 8 Part No. 900 611<br />

3 x DB M 1 255 FM Part No. 961 125<br />

1 x DGP M 255 FM Part No. 961 105<br />

1 x MVS 1 8 Part No. 900 611<br />

fault indication<br />

1 x DV M TT 255 FM Part No. 951 315<br />

alt. 1 x DV M TT 255 Part No. 951 310<br />

1) Only required, if no fuse of the same or a lower nominal value is provided in the upstream power supply.<br />

L1 L2 L3 N<br />

TT system: Example: Industrial building<br />

20<br />

www.dehn.de