Accessory for Terminal Block Systems<br />

Shield Connection on Anchor Bars<br />

• Lightning-impulse-current-tested up to 10 kA<br />

(10/350 μs)<br />

• Corrosion-resistant stainless steel<br />

• Spring element ensures permanent shield<br />

connection<br />

Lightning current carrying shield connection system for anchor bars.<br />

A slipping spring element compensates the yield of the cable materials<br />

used.<br />

The lightning-impulse-current-tested shield connection system is specifically<br />

used on anchor bars. As, in the course of time, the conductor materials<br />

are subject to a yield, this yield is compensated by a slipping spring<br />

element. The shield connection can also be isolated from local potential<br />

by means of an adequate insulating element.<br />

This very robust shield connection<br />

system is particularly suited<br />

for cables with medium-sized<br />

diameters. It has been tested<br />

with lightning currents and is<br />

approved for nuclear plants.<br />

Shield connection system on<br />

anchor bar<br />