Easy Choice<br />

L1 L2 L3 N PE<br />

SPD Type 3<br />

(Surge arrester)<br />

SPD Type 3<br />

(Surge arrester)<br />

Cable length ≥ 5 m<br />

1 9 2<br />

50<br />

DEHNrail<br />

DR M 2P 255 FM<br />

heating<br />

1 x DR M 2P 255 Part No. 953 200<br />

Heating Control<br />

PROTECTOR<br />

1 x DPRO 230 Part No. 909 230<br />

1 x DPRO 230 F Part.-Nr. 909 240<br />

1 x SFL PRO Part No. 912 260<br />

Socket Outlet<br />

16 A<br />

PEN<br />

L1<br />

L2<br />

L3<br />

KW h<br />

DEHNventil ZP<br />

DV ZP TNC 255<br />

9 PEN<br />

SPD Type 1<br />

(Combined lightning current<br />

and surge arrester)<br />

1 x DV ZP TNC 255 Part No. 900 390<br />

also available for 5-wire systems<br />

1 x DV ZP TT 255 Part No. 900 391<br />

Note:<br />

As an alternative, surge arresters can also be<br />

used downstream of meter panels<br />

(e.g. DG M TNC 275 Part No. 952 300)<br />

if there is no<br />

– lightning protection system<br />

– electrical power supply by the service entry mast<br />

– antenna of the roof<br />

– if none of the conditions mentioned above<br />

apply to an adjoining building<br />

Central Main and<br />

Sub-distribution Board<br />

315 A<br />

MEB<br />

L1 L2 L3 PEN<br />

TN system: Example: Single-family house<br />

L1 L2 L3 N PE<br />

SPD Type 3<br />

(Surge arrester)<br />

SPD Type 3<br />

(Surge arrester)<br />

Cable length ≥ 5 m<br />

1 9 2<br />

DEHNrail<br />

DR M 2P 255 FM<br />

heating<br />

Heating Control<br />

DEHNflex<br />

Socket Outlet<br />

1 x DR M 2P 255 Part No. 953 200<br />

1 x DFL M 255 Part No. 924 396<br />

16 A<br />

RCD<br />

125 A<br />

L1<br />

DEHNventil<br />

DV MOD 255<br />

L2<br />

DEHNventil<br />

DV MOD 255<br />

L3<br />

DEHNventil<br />

DV MOD 255<br />

N<br />

9<br />

DEHNventil<br />

DV MOD NPE<br />

PE<br />

SPD Type 1<br />

(Combined lightning current<br />

and surge arrester)<br />

1 x DV M TT 255 Part No. 951 310<br />

Note:<br />

As an alternative, surge arresters can also be<br />

used downstream of meter panels<br />

(e.g. DG M TT 275 Part No. 952 310)<br />

if there is no<br />

– lightning protection system<br />

– electrical power supply by the service entry mast<br />

– antenna of the roof<br />

– if none of the conditions mentioned above<br />

apply to an adjoining building<br />

Central Main and<br />

Sub-distribution Board<br />

MEB<br />

L1 L2 L3 N<br />

TT system: Example: Single-family house<br />

18<br />

www.dehn.de

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!