DEHNguard ® modular with integrated Backup Fuse<br />

DEHNguard M TNC CI ... (FM)<br />

L1 L2 L3<br />

Type 2 Surge Arresters<br />

30<br />

L1 L2 L3<br />

12<br />

11<br />

14<br />

90<br />

45<br />

PEN<br />

54 7<br />

(3 mods.)<br />

43.5<br />

66<br />

9<br />

PEN<br />

15.3<br />

9<br />

11<br />

• Arrester backup fuse integrated in the<br />

protection module<br />

• Prewired complete unit consisting of a<br />

base part and plug-in protection modules<br />

• High reliability due to "Thermo Dynamic<br />

Control" SPD monitoring device<br />

Basic circuit diagram DG M TNC CI ... FM<br />

Modular surge arrester with integrated backup fuses for TN-C systems<br />

Dimension drawing DG M TNC CI ... FM<br />

Surge Arresters Type 2<br />

Type DG M TNC CI 275 DG M TNC CI 275 FM<br />

Part No. 952 304 952 309<br />

SPD according to EN 61643-11 Type 2 Type 2<br />

SPD according to IEC 61643-1/-11 Class II Class II<br />

Nominal a.c. voltage (U N ) 230/400 V 230/400 V<br />

Max. continuous operating a.c. voltage (U C ) 275 V 275 V<br />

Nominal discharge current (8/20 μs) (I n ) 12.5 kA 12.5 kA<br />

Max. discharge current (8/20 μs) (I max ) 25 kA 25 kA<br />

Voltage protection level (U P ) ≤ 1.5 kV ≤ 1.5 kV<br />

Voltage protection level at 5 kA (U P ) ≤ 1 kV ≤ 1 kV<br />

Response time (t A ) ≤ 25 ns ≤ 25 ns<br />

Max. mains-side overcurrent protection not required not required<br />

Short-circuit withstand capability 25 kA rms 25 kA rms<br />

Temporary overvoltage (TOV) (U T ) 335 V / 5 sec. 335 V / 5 sec.<br />

TOV characteristics withstand withstand<br />

Operating temperature range (T U ) -40°C...+80°C -40°C...+80°C<br />

Operating state/fault indication green / red green / red<br />

Number of ports 1 1<br />

Cross-sectional area (min.) 1.5 mm 2 solid/flexible 1.5 mm 2 solid/flexible<br />

Cross-sectional area (max.) 35 mm 2 stranded/25 mm 2 flexible 35 mm 2 stranded/25 mm 2 flexible<br />

For mounting on 35 mm DIN rail acc. to EN 60715 35 mm DIN rail acc. to EN 60715<br />

Enclosure material thermoplastic, red, UL 94 V-0 thermoplastic, red, UL 94 V-0<br />

Place of installation indoor installation indoor installation installation<br />

Degree of protection IP 20 IP 20<br />

Capacity 3 modules, DIN 43880 3 modules, DIN 43880<br />

Approvals KEMA, VDE KEMA, VDE<br />

Type of remote signalling contact –– changeover contact<br />

a.c. switching capacity –– 250 V/0.5 A<br />

d.c. switching capacity –– 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A<br />

Cross-sectional area for remote signalling terminals –– max. 1.5 mm 2 solid/flexible<br />

952 304<br />

DG M TNC CI 275<br />

952 309<br />

DG M TNC CI 275 FM<br />

DG M TNC CI 275<br />

952 304<br />

Überspannungsableiter Typ 2 DEHNguard M 3-polig für TN-C-Systeme<br />

DG M TNC CI 275 FM<br />

952 309<br />

Überspannungsableiter Typ 2 DEHNguard M 3-polig für TN-C-Systeme<br />

Accessory for DEHNguard ® modular with integrated<br />

Backup Fuse<br />

Varistor-Based Protection Module for<br />

DEHNguard M CI<br />

Protection module for DEHNguard M ... CI 275 arresters<br />

comprising a varistor connected in series with the integrated<br />

backup fuse<br />

Type DG MOD CI 275<br />

Part No. 952 020<br />

Max. continuous operating a.c. voltage (U C ) 275 V<br />