DEHNrapid ® LSA<br />

DRL RD<br />

SPDs for LSA Technology<br />

a<br />

a´<br />

1 2 3 4 5 6 7 8 9 0<br />

IN<br />

OUT<br />

22<br />

9.4<br />

8.5<br />

33.4<br />

b<br />

b´<br />

• Low voltage protection level line/line<br />

for protecting terminal equipment<br />

• Energy-coordinated with DRL plug-in<br />

SPD block<br />

• For installation in conformity with the<br />

lightning protection zones concept at<br />

the boundaries from 1 – 2 and higher<br />

Basic circuit diagram DRL RD<br />

Dimension drawing DRL RD<br />

Protective plug (one pair), energy-coordinated with DRL plug-in SPD block, for use as single-stage<br />

protective device for terminal equipment. Low voltage protection level line-line for unearthed interfaces.<br />

To be mounted into EF 10 DRL. Installation recommended only in combination with DRL plugin<br />

SPD block.<br />

Type DRL RD 5 DRL RD 12 DRL RD 24 DRL RD 48 DRL RD 60 DRL RD 110<br />

Part No. 907 440 907 441 907 442 907 443 907 444 907 445<br />

SPD class O O O O O O<br />

Nominal voltage (U N ) 5 V 12 V 24 V 48 V 60 V 110 V<br />

Max. continuous operating d.c. voltage (U C ) 6 V 14 V 28 V 54 V 70 V 180 V<br />

Max. continuous operating a.c. voltage (U C ) 4.2 V 9.5 V 19.5 V 38 V 49.5 V 127 V<br />

Nominal current (I L ) 0.4 A 0.4 A 0.4 A 0.4 A 0.4 A 0.4 A<br />

D1 Total lightning impulse current (10/350 μs)<br />

in combination with DRL 10 B... (I imp ) 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA<br />

D1 Lightning impulse current (10/350 μs)<br />

per line in combination with DRL 10 B... (I imp ) 2.5 kA 2.5 kA 2.5 kA 2.5 kA 2.5 kA 2.5 kA<br />

C2 Total nominal discharge current (8/20 μs)<br />

in combination with DRL 10 B... (I n ) 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA<br />

C2 Nominal discharge current (8/20 μs)<br />

per line in combination with DRL 10 B... (I n ) 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA<br />

Voltage protection level line-PG for I imp D1<br />

in combination with DRL 10 B... (U p ) ≤ 500 V ≤ 500 V ≤ 500 V ≤ 500 V ≤ 500 V ≤ 500 V<br />

Voltage protection level line-line<br />

at 1 kV/μs C3 (U p ) ≤ 8.5 V ≤ 18 V ≤ 36 V ≤ 70 V ≤ 95 V ≤ 250 V<br />

Series impedance per line 2.2 ohms 2.2 ohms 2.2 ohms 4.7 ohms 4.7 ohms 4.7 ohms<br />

Cut-off frequency line-line (f G ) 1 MHz 2.7 MHz 5.4 MHz 7.8 MHz 11 MHz 20 MHz<br />

Capacitance line-line (C) ≤ 5.5 nF ≤ 2.0 nF ≤ 1.1 nF ≤ 700 pF ≤ 500 pF ≤ 200 pF<br />

Operating temperature range -40°C...+80°C -40°C...+80°C -40°C...+80°C -40°C...+80°C -40°C...+80°C -40°C...+80°C<br />

Degree of protection<br />

IP 20 (when plugged in)<br />

Plugs into<br />

LSA disconnection block 2/10 or DRL 10 B... plug-in SPD block<br />

Enclosure material polyamide PA 6.6 polyamide PA 6.6 polyamide PA 6.6 polyamide PA 6.6 polyamide PA 6.6 polyamide PA 6.6<br />

Colour yellow yellow yellow yellow yellow yellow<br />

Test standards IEC 61643-21 / IEC 61643-21 / IEC 61643-21 / IEC 61643-21 / IEC 61643-21 / IEC 61643-21 /<br />

EN 61643-21 EN 61643-21 EN 61643-21 EN 61643-21 EN 61643-21 EN 61643-21<br />

Approvals VdS, GOST VdS, GOST VdS, GOST VdS, GOST VdS, GOST GOST<br />

907 440<br />

DRL RD 5<br />

907 441<br />

DRL RD 12<br />

907 442<br />

DRL RD 24<br />

DRL 907 443 RD 5<br />

907 DRL 440 RD 48<br />

Überspannungsableiter 907 444<br />

DEHNrapid LSA Schutzstecker für 1 Doppelader Un<br />

5V DRL RD 60<br />

DRL 907 445 RD 12<br />

907 DRL 441 RD 110<br />

Überspannungsableiter DEHNrapid LSA Schutzstecker für 1 Doppelader Un<br />

12V<br />

DRL RD 24<br />

907 442<br />

Überspannungsableiter DEHNrapid LSA Schutzstecker für 1 Doppelader Un<br />

24V<br />

DRL RD 48<br />

907 443<br />

Überspannungsableiter DEHNrapid LSA Schutzstecker für 1 Doppelader Un<br />

48V<br />

DRL RD 60<br />

907 444<br />

Überspannungsableiter DEHNrapid LSA Schutzstecker für 1 Doppelader Un<br />

60V<br />

DRL RD 110<br />

907 445<br />

Überspannungsableiter DEHNrapid LSA Schutzstecker für 1 Doppelader Un<br />

110V<br />

Accessory for DEHNrapid ® LSA<br />

Earthing Frame<br />

Snap-on earthing frame for earthing and mounting of<br />

max. 10 DRL protective plugs. Plugs into a 10-pair disconnection<br />

block or DRL plug-in SPD block.<br />

Type<br />

EF 10 DRL<br />

Part No. 907 498<br />

Colour<br />

yellow<br />

Accessory for DEHNrapid ® LSA<br />

Label Holder<br />

Universal label holder made of stainless steel for clear<br />

identification of LSA connections. Can be snapped onto<br />

DEHNrapid LSA plug-in SPD blocks, earthing frames<br />

with protective plugs or mounting frames with LSA SPD<br />

blocks of 2/10 type.<br />

Type<br />

SR DRL<br />

Part No. 907 497<br />

Material<br />

Stainless steel<br />

236 www.dehn.de