<strong>ASD</strong>/<strong>LRFD</strong> MANUAL FOR ENGINEERED <strong>Wood</strong> Construction<br />

115<br />

Figure M16.1-11 One-Hour Fire-Resistive <strong>Wood</strong> Floor/Ceiling Assembly<br />

(2x10 <strong>Wood</strong> Joists 16" o.c. – Suspended Acoustical Ceiling Panels)<br />

1. Nominal 19/32 in. T&G plywood underlayment (single<br />

floor). Oriented strand board (OSB) panels are permitted<br />

for certain designs.<br />

2. Building paper.<br />

3. 15/32 in. plywood subfloor. Subfloors for certain designs<br />

may be nom. 7/16 in. OSB.<br />

4. 2x10 wood joists spaced 16 in. o.c.<br />

5. T-bar grid ceiling system.<br />

6. Main runners spaced 48 in. o.c.<br />

7. Cross-tees spaced 24 in. o.c.<br />

8. 1/2 in. x 24 in. x 48 in. mineral acoustical ceiling panels<br />

installed with holddown clips.<br />

Fire Tests:<br />

UL L209<br />

M16: FIRE DESIGN<br />

16<br />