118 M16: FIRE DESIGN<br />

Figure M16.1-14 Two-Hour Fire-Resistive <strong>Wood</strong> Floor/Ceiling Assembly<br />

(2x10 <strong>Wood</strong> Joists 16" o.c. – Gypsum Directly Applied with Second Layer on Resilient<br />

Channels)<br />

1. Nominal 1 in. wood flooring or 19/32 in. T&G plywood<br />

underlayment (single floor). Oriented strand<br />

board (OSB) panels are permitted for certain designs.<br />

2. Building paper.<br />

3. Nominal 1x6 T&G boards or 15/32 in. plywood subfloor.<br />

Subfloors for certain designs may be nominal<br />

7/16 in. OSB.<br />

4. 5/8 in. proprietary Type X Gypsum Wallboard ceiling<br />

attached directly to joists.<br />

5. 2x10 wood joists space 16 in. o.c.<br />

6. Resilient channels.<br />

7. 5/8 in. proprietary Type X Gypsum Wallboard ceiling<br />

attached to resilient channels.<br />

Fire Tests:<br />

UL R1319-114, 7-21-67, Design L511<br />

UL R2717-35, 10-21-64, Design L505; ULC Design<br />

M503<br />

<strong>American</strong> <strong>Wood</strong> <strong>Council</strong>