66 M9: WOOD STRUCTURAL PANELS<br />
M9.3 Adjustment of Reference Design Values<br />
General<br />
Adjusted panel design capacities are determined by<br />
multiplying reference capacities, as given in Tables M9.2-<br />
1 through M9.2-4, by the adjustment factors in NDS 9.3.<br />
Some adjustment factors should be obtained from the<br />
manufacturer or other approved source. In the NDS Commentary,<br />
C9.3 provides additional information on typical<br />
adjustment factors.<br />
Tabulated capacities provided in this Chapter are<br />
suitable for reference end-use conditions. Reference<br />
end-use conditions are consistent with conditions typically<br />
associated with light-frame construction. For wood<br />
structural panels, these typical conditions involve the use<br />
of full-sized untreated panels in moderate temperature and<br />
moisture exposures.<br />
Appropriate adjustment factors are provided for applications<br />
in which the conditions of use are inconsistent<br />
with reference conditions. In addition to temperature and<br />
moisture, this includes consideration of panel treatment<br />
and size effects.<br />
NDS Table 9.3.1 lists applicability of adjustment factors<br />
for wood structural panels. Table M9.3-1 shows the<br />
applicability of adjustment factors for wood structural<br />
panels in a slightly different format for the designer.<br />
Table M9.3-1<br />
Applicability of Adjustment Factors for <strong>Wood</strong> Structural Panels<br />
Allowable Stress Design<br />
F b S′ = F b S C D C M C t C G C s<br />
F t A′ = F t A C D C M C t C G C s<br />
F v t v ′ = F v t v C D C M C t C G<br />
F s (Ib/Q)′ = F s (Ib/Q) C D C M C t C G<br />
F c A′ = F c A C D C M C t C G<br />
EI′ = EI C M C t C G<br />
EA′ = EA C M C t C G<br />
G v t v ′ = G v t v C M C t C G<br />
F c⊥ ′ = F c⊥ C M C t C G<br />
Bending Member Example<br />
For non-Structural I grade wood structural panels,<br />
greater than 24" in width, loaded in bending, and used<br />
in a normal building environment (meeting the reference<br />
conditions of NDS 2.3 and 9.3), the adjusted design values<br />
reduce to:<br />
For <strong>ASD</strong>:<br />
F b S′ = F b S C D<br />
EI′ = EI<br />
For <strong>LRFD</strong>:<br />
F b S′ = F b S K F φ b λ<br />
EI′ = EI<br />
Load and Resistance Factor Design<br />
F b S′ = F b S C M C t C G C s K F φ b λ<br />
F t A′ = F t A C M C t C G C s K F φ t λ<br />
F v t v ′ = F v t v C M C t C G K F φ v λ<br />
F s (Ib/Q)′ = F s (Ib/Q) C M C t C G K F φ v λ<br />
F c A′ = F c A C M C t C G K F φ c λ<br />
EI′ = EI C M C t C G<br />
EA′ = EA C M C t C G<br />
G v t v ′ = G v t v C M C t C G<br />
F c⊥ ′ = F c⊥ C M C t C G K F φ c λ<br />
Axially Loaded Member Example<br />
For non-Structural I grade wood structural panels,<br />
greater than 24" in width, axially loaded, and used in a<br />
normal building environment (meeting the reference conditions<br />
of NDS 2.3 and 4.3) designed to resist tension or<br />
compression loads, the adjusted tension or compression<br />
design values reduce to:<br />
For <strong>ASD</strong>:<br />
F c A′ = F c A C D<br />
F t A′ = F t A C D<br />
EA′ = EA<br />
For <strong>LRFD</strong>:<br />
F c A′ = F c A K F φ c λ<br />
F t A′ = F t A K F φ t λ<br />
EA′ = EA<br />
<strong>American</strong> <strong>Wood</strong> <strong>Council</strong>