138 M16: FIRE DESIGN<br />

NER – 392 WTCA – FR-SYSTEM 2<br />

(floor or roof - optional insulation)<br />

Fire Rating: 2 Hr<br />

Finish Rating: 65 Minutes<br />

Construction: <strong>Wood</strong> trusses (nominal 2x3) 24" oc, minimum<br />

16" depth<br />

2" shield member attached to bottom chord<br />

FR-Quik Channel Sets and Bond<br />

Washers by Alpine Engineered Products<br />

Note: alternate installation with resilient<br />

channel added<br />

Two layers 5/8" proprietary Type X gypsum<br />

board<br />

Sheathing minimum 23/32"<br />

PFS 89-71, FR-SYSTEM 6<br />

(floor or roof - optional insulation)<br />

Fire Rating: 2 Hr<br />

Finish Rating: 100+ Minutes<br />

Construction: <strong>Wood</strong> trusses 24" oc, minimum depth 9-1/4"<br />

Resilient channel 16" oc<br />

Three layers 5/8" proprietary Type X gypsum<br />

board<br />

Sheathing minimum 23/32"<br />

UL L-556, GA FC 5751, and RC 2751<br />

(floor or roof – alternate truss configuration)<br />

Fire Rating: 2 Hr<br />

Finish Rating: 2 Hr<br />

Construction: <strong>Wood</strong> trusses 24" oc, minimum 18" depth<br />

Resilient channel 24" oc<br />

Four layers 5/8" gypsum board<br />

Sheathing 23/32"<br />

UL L577<br />

(floor or roof - insulation)<br />

Fire Rating: 2 Hr<br />

Construction: <strong>Wood</strong> trusses 24" oc, minimum 12" depth<br />

Resilient or furring channel 16" oc<br />

Three layers 5/8" proprietary Type X gypsum<br />

board<br />

Sheathing minimum 23/32"<br />

<strong>American</strong> <strong>Wood</strong> <strong>Council</strong>