<strong>ASD</strong>/<strong>LRFD</strong> MANUAL FOR ENGINEERED <strong>Wood</strong> Construction<br />
M16.1-11 One-Hour Fire-Resistive <strong>Wood</strong><br />
Floor/Ceiling Assembly (2x10 <strong>Wood</strong> Joists<br />
16" o.c. – Suspended Acoustical Ceiling<br />
Panels)....................................................... 115<br />
M16.1-12 One-Hour Fire-Resistive <strong>Wood</strong> Floor/Ceiling<br />
Assembly (2x10 <strong>Wood</strong> Joists 16" o.c.<br />
– Gypsum on Resilient Channels)............ 116<br />
M16.1-13 One-Hour Fire-Resistive <strong>Wood</strong><br />
Floor/Ceiling Assembly (2x10 <strong>Wood</strong><br />
Joists 24" o.c. – Gypsum on Resilient<br />
Channels).................................................. 117<br />
M16.1-14 Two-Hour Fire-Resistive <strong>Wood</strong><br />
Floor/Ceiling Assembly (2x10 <strong>Wood</strong><br />
Joists 16" o.c. – Gypsum Directly Applied<br />
with Second Layer on Resilient<br />
Channels).................................................. 118<br />
M16.1-15 One-Hour Fire-Resistive Ceiling Assembly<br />
(WIJ-1.1) (Floor/Ceiling - 100% Design<br />
Load - 1-Hour Rating - ASTM<br />
E119/NFPA 251)....................................... 124<br />
M16.1-16 One-Hour Fire-Resistive Ceiling<br />
Assembly (WIJ-1.2) (Floor/Ceiling -<br />
100% Design Load - 1 Hour Rating -<br />
ASTM E119/NFPA 251)........................... 125<br />
M16.1-17 One-Hour Fire-Resistive Ceiling<br />
Assembly (WIJ-1.3) (Floor/Ceiling -<br />
100% Design Load - 1-Hour Rating -<br />
ASTM E119/NFPA 251)........................... 126<br />
M16.1-18 One-Hour Fire-Resistive Ceiling<br />
Assembly (WIJ-1.4) (Floor/Ceiling -<br />
100% Design Load - 1-Hour Rating -<br />
ASTM E119/NFPA 251)........................... 127<br />
M16.1-19 One-Hour Fire-Resistive Ceiling<br />
Assembly (WIJ-1.5) (Floor/Ceiling -<br />
100% Design Load - 1-Hour Rating -<br />
ASTM E119/NFPA 251)........................... 128<br />
M16.1-20 One-Hour Fire-Resistive Ceiling<br />
Assembly (WIJ-1.6) (Floor/Ceiling -<br />
100% Design Load - 1-Hour Rating -<br />
ASTM E119/NFPA 251)........................... 129<br />
M16.1-21 Two-Hour Fire-Resistive Ceiling<br />
Assembly (WIJ-2.1) (Floor/Ceiling -<br />
100% Design Load - 2-Hour Rating -<br />
ASTM E119/NFPA 251)........................... 130<br />
M16.1-22 Cross Sections of Possible One-Hour<br />
Area Separations....................................... 139<br />
M16.1-23 Examples of Through-Penetration<br />
Firestop Systems....................................... 142<br />
M16.3-1 Beam to Column Connection -<br />
Connection Not Exposed to Fire............... 159<br />
M16.3-2 Beam to Column Connection - Connection<br />
Exposed to Fire Where Appearance is a<br />
Factor........................................................ 159<br />
M16.3-3 Ceiling Construction ................................ 159<br />
M16.3-4 Beam to Column Connection - Connection<br />
Exposed to Fire Where Appearance is<br />
Not a Factor.............................................. 159<br />
M16.3-5 Column Connections Covered ................. 160<br />
M16.3-6 Beam to Girder - Concealed<br />
Connection................................................ 160<br />
<strong>American</strong> <strong>Wood</strong> <strong>Council</strong>