Use FP-ROM area as backup data(<strong>ZM</strong>80 function) (corresponds to page 2-23)<br />

<br />

The remaining area in the screen data FP-ROM (flash memory) can be used for PLC<br />

memory, internal memory, or memory card for data backup. A maximum of 16k words is<br />

usable as the data backup area.<br />

* The capacity of the display data will be reduced by 128kbytes.<br />

Setting procedure<br />

Choose [Others] from [System Setting]. The [Other Settings] dialog is displayed. In the<br />

[P3] tab window, check [Use Internal Flash ROM as Back-up Area].<br />

Data backup procedure<br />

Data can be written to the FP-ROM at one time by macro command [FROM_WR].<br />

For reading backup data from the FP-ROM, use the macro command [FROM_RD].<br />

[FROM_WR]<br />

The number of words (maximum 16K words) specified for F1 are written from the F0<br />

memory to the FP-ROM.<br />

Usable devices<br />

Internal memory PLC memory Constant Memory card Indirect set Word<br />

F0 <br />

F1 <br />

FROM_WR : Writing to FROM FROM_WR F0<br />

F1<br />

[FROM_RD]<br />

The number of words (maximum 16K words) specified for F1 are read from the FP-ROM<br />

to the F0 memory.<br />

Usable devices<br />

Internal memory PLC memory Constant Memory card Indirect set Word<br />

F0 <br />

F1 <br />

FROM_RD : Read to FROM FROM_RD F0 F1<br />

1. It will be possible to write to the FP-ROM one hundred thousand times.<br />

(One execution of [FROM_WR] is counted as one time, irrespective of the<br />

specified number of words.)<br />

It is recommended that backup data be read at power-on and be written<br />

before power-down.<br />

2. <strong>About</strong> 3 to 5 seconds will be necessary for writing to the FP-ROM.<br />

3.Do not execute [FROM_WR] or [FROM_RD] in every cycle using cycle<br />

macro, etc.<br />

4.When reading the words by [FROM_RD] more than the words written by<br />

[FROM_WR], the [FROM_RD] is not executed.<br />

The value [-1] is written to $s728 (refer to the next section.)<br />

<strong>About</strong> system memory (s)<br />

The following system memory ($s) is related to the use of the FP-ROM as the data backup<br />

area.<br />

- Address s728<br />

A result by the execution of [FROM_WR] or [FROM_RD] is written to this address.<br />

[0]: Normal [-1]: Abnormal