Press the [Cassette Adjustment] switch.<br />

This switch is valid for the FONT <strong>version</strong> 1.100/1.090/1.000 or greater.<br />

2Press the [Cassette Adjustment] switch.<br />

The [Cassette Adjustment] screen is displayed.<br />

3Press the [Format] switch and then the [Execute] switch.<br />

The cassette is formatted according to the current screen data. The [Main Menu] screen<br />

is displayed again.<br />

Cassette Adjustment<br />

2000-6-26 14:38:51<br />

Main Menu<br />

Date and Time Adjustment<br />

Date:<br />

Time:<br />

+ -<br />

Set<br />

Format of SRAM Cassette<br />

* Formats SRAM cassette in the present screen data type.<br />

Format<br />

Execute<br />

Additional error numbers to be displayed on the <strong>ZM</strong><br />

The following new error numbers are provided for check errors.<br />

Check<br />

Data has some error.<br />

Data has some error.<br />

Error:160 (24 : )<br />

Error:160 (24 : )<br />

Error No.<br />

Item No.<br />

Item number<br />

24: SRAM cassette<br />

Error number (Refer to the following table.)<br />

<strong>ZM</strong>80 <strong>ZM</strong>70 Error No. Contents Remedies<br />

<br />

<br />

160<br />

There is an error in the [SRAM<br />

Cassette Setting] dialog.<br />

(The total words exceed 256k words.)<br />

Reduce the total number of words<br />

to 256k or less in the dialog.<br />

<br />

<br />

161<br />

The SRAM cassette data is<br />

destroyed.<br />

Check the battery for voltage<br />

drop and contact our technical<br />

support department.<br />

<br />

<br />

162<br />

The SRAM cassette data does not<br />

match the <strong>ZM</strong> program <strong>version</strong>.<br />

Check both <strong>version</strong>s and contact<br />

our technical support department.<br />

<br />

<br />

163<br />

The setting in the [SRAM Cassette<br />

Setting] dialog does not match the<br />

SRAM cassette format.<br />

Check the [SRAM Cassette<br />

Setting] data and execute<br />

formatting of the SRAM cassette.<br />

<br />

<br />

205<br />

The [SRAM Cassette Setting] dialog<br />

has been set, but no SRAM cassette<br />

is attached.<br />

Attach an SRAM cassette.