ZM-71SE About version 1.2.1.0 - Soliton
ZM-71SE About version 1.2.1.0 - Soliton
ZM-71SE About version 1.2.1.0 - Soliton
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Ethernet<br />
These commands are available when using Ethernet communication in <strong>ZM</strong>80.<br />
For more information about them, refer to the manual, "<strong>ZM</strong>-80NU Network Module Instruction<br />
Manual."<br />
SEND/EREAD/EWRITE<br />
SYS Commands (corresponds to page 14-13)<br />
Calculation SYS F0 F1<br />
Description<br />
According to information taken from the <strong>ZM</strong>80 Series, an action<br />
specified in F0 is requested to the <strong>ZM</strong>80 Series through the internal<br />
memory specified in F1.<br />
Command<br />
SET_SCRN<br />
SET_MOVLP<br />
OVLP_SHOW<br />
OVLP_POS<br />
GET_TIME<br />
STA_TIME<br />
CHK_TIME<br />
GET_CLND<br />
SET_CLND<br />
GET_SMPL<br />
GET_SCUR<br />
SET_BUFNO<br />
GET_MSG<br />
STA_LIST<br />
OUT_ENQ<br />
DSP_DATA<br />
CHG_DATA<br />
GET_XY<br />
SET_BZ<br />
SET_RGB<br />
SET_BKLT<br />
Contents<br />
Screen number setting<br />
Multi-overlap setting<br />
Overlap On/Off<br />
Overlap position setting<br />
Get the system time<br />
Start the timer<br />
Check the time of the timer<br />
Get the calendar<br />
Calendar setting<br />
Get sampled data<br />
Get the cursor point of sampling<br />
Buffer number setting<br />
Get the message<br />
Print out the data sheet<br />
Interrupt via serial port<br />
in the <strong>ZM</strong>70 :<br />
in the <strong>ZM</strong>70 :<br />
in the <strong>ZM</strong>70 :<br />
Display/not display the data display (=numeric data)<br />
Change the property of the data display (=numeric data)<br />
Get the X and Y coordinates<br />
Buzzer ON/OFF<br />
For <strong>ZM</strong>80 analog RGB input type<br />
Backlight control<br />
Additional<br />
items<br />
These macros cannot be executed by Initial Macro and screen OPEN/CLOSE Macro. Moreover,<br />
these system calls are not immediately executed, but rather, are executed when the<br />
entire macro has been completed.<br />
Only one system call is active for each window. If there is already a call for a window, any<br />
other system calls for the same window are ignored.<br />
Additionally, if [SET_MOVLP] is executed for Overlap No. 0 and [OVLP_SHOW] is given for<br />
the same overlap, the latter is ignored.<br />
Macro command<br />
RGB_CHG<br />
These commands are available only when using <strong>ZM</strong>72TR analog RGB input type.<br />
For more information about it, refer to Specification of Analog RGB Input.<br />
Expanded transit size<br />
Command [Conventional size] [<strong>ZM</strong>-71S Ver.1.2.0.0 or later]<br />
BMOVNo. of blocks<br />
FILLNo. of blocks<br />
1,024<br />
4,096<br />
FORNo. of loops 2,500<br />
65,535