Address $s76 (correspondense to page 15-11)<br />

If a keypad for Entry mode is placed on an overlap, it is possible to turn OFF the overlap<br />

when pressing the [ENT] key of a keypad.<br />

If you want to prohibit the above function, use this system memory address.<br />

When the value except for [0] is set, the Auto-OFF function of an overlap is prohibited. For<br />

more information, refer to the "Chapter 9 Entry Mode" page 9-15.<br />

Address $s77 (<strong>ZM</strong>80 Function)<br />

When inputting the value except for [0], the exclusive function of overlap is valid.<br />

For more information, refer to the "Chapter 4 Overlap" page 4-12.<br />

Address $s100, 101 (corresponds to page 15-11)<br />

These are the memories related to calendar.<br />

$s100: Write the calendar condition at the PLC (with a built-in calendar) side.<br />

[0] : normal<br />

[1] : error (cannot read the calendar information.)<br />

$s101: Writing the data to calendar on a PLC (e.g. : [SET_CLND] on macro commands) will<br />

be accessible regardless of the condition of PLC calendar, by setting the value except<br />

for [0] in this memory. The error is not processed even if the error is detected.<br />

(Before this <strong>version</strong>, it is impossible to write the data when the condition of calendar<br />

on PLC has some error.)<br />

Address $s104, 105 (<strong>ZM</strong>80 Function)<br />

Specify the error processing of <strong>ZM</strong>80 reading/writing the data to a PLC by macro commands<br />

when communicating with a PLC.<br />

For example, when the writing target memory address is specified as the indirect PLC<br />

memory in the MOV command, the communication error will happen as soon as the value of<br />

the indirect PLC memory exceeds the range of the PLC side.<br />

This command can prevent the above communication error.<br />

$s104: When the value is [0], the error is processed when the error occurs in reading/writing<br />

the data. The processing way is defined by the setting of [Comm. Error Handling]<br />

(Stop/Continuous) at the [Comm. Parameter]. When reading data, the next macro<br />

command executes after receiving for the result. The write command of macro is<br />

unilateraly sent, and the next command is executed without waiting for the result of<br />

the write command. When setting the value except for [0], only the result is stored<br />

into the memory $s105.<br />

When sending the read/write command of macro, the next command is not executed<br />

until receiving the result whether the action is finished or not after the order for writing<br />

is given. So, it takes more time to process than [0] (normal).<br />

$s105: The result of error is output by [0] (normal) or except for [0] (error).<br />

Address $s106, 107 (<strong>ZM</strong>80 Function)<br />

<br />

When using Memo Pad Function, store the information about Memo Pad Function.<br />

$s106: Store the page number of the present displayed memo pad.(Page No. : 0~7)<br />

$s107: Store the information whether the data is registered or not in each page of memo pad<br />

(the maximum 8 pages). 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0<br />

0 : Data unregistered<br />

1 : Data registered<br />

<br />

Page 0<br />

Page 1<br />

Page 2<br />

Page 3<br />

Page 4<br />

Page 5<br />

Page 6<br />

Page 7