When setting in the [Detail] tab window of the [Num Display] dialog:<br />

[Alarm]<br />

The specified maximum and minimum values are compared with converted and displayed<br />

values.<br />

Ex.)<br />

In the case of [Input Range: 0 - 4000], [Display Range: 0 - 50], and [Max.: 40] and [Min.:<br />

10] for [Alarm]: An upper limit alarm is given when the PLC memory D100 is set to “3200,”<br />

and a lower alarm is given when it is set to “800.”<br />

[Use Operation]<br />

A correct result will not be given if a value becomes larger than double word halfway<br />

through operation.