5 Program Stop Time ($s440, 441)<br />
= Sampling bit reset time<br />
U1<br />
U2<br />
U3<br />
Sampling Monitored<br />
Sampling Monitored<br />
Sampling bit (U)<br />
OFF<br />
t1<br />
t2<br />
Normal operation bit (S)<br />
OFF T1 T2 T3 T4<br />
Error bit<br />
OFF<br />
1. = T1 + T2 + T3 + T4<br />
2. = t1 + t2<br />
3. = 1. + 2.<br />
4. = 1. / 3. x 100<br />
5. = U1 + U2 + U3<br />
It is recommended that you use the [Time Display] item to display these times on<br />
the screen. For details, refer to page 12-62 in Instruction Manual.<br />
6 Buffer Nos. 0 to 11 normal operation bit ($s456)<br />
Enter the normal operation bit status for buffer numbers 0 to 11.<br />
$s456<br />
MSB<br />
LSB<br />
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00<br />
0 0 0 0 S S S S S S S S S S S S<br />
Buffer No. 0<br />
No. 11<br />
No. 1<br />
No. 10<br />
No. 2<br />
No. 9 No. 8 No. 7 No. 6 No. 5 No. 4 No. 3<br />
Normal operation bit<br />
7 Buffer Nos. 0 to 11 sampling bit ($s458)<br />
Enter the sampling bit status for buffer numbers 0 to 11.<br />
$s458<br />
MSB<br />
LSB<br />
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00<br />
0 0 0 0 U U U U U U U U U U U U<br />
Buffer No. 0<br />
No. 11<br />
No. 1<br />
No. 10<br />
No. 2<br />
No. 9 No. 8 No. 7 No. 6 No. 5 No. 4 No. 3<br />
Sampling bit