12.07.2015 Views

Acta Facultatis Ecologiae - Technická univerzita vo Zvolene

Acta Facultatis Ecologiae - Technická univerzita vo Zvolene

Acta Facultatis Ecologiae - Technická univerzita vo Zvolene

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

59Tab. 6: ContinuedSamples withsurface 40 m 2 with BackgroundResultsbackgroundVOC µg.m –3 µg.m –3 µg.m –3o-Xylene 0.5 0.5 0Butoxy-Ethanol 0.1 0.1 0.1Α-Pinene 0 0 0Camphene 0 0 0p-Cymene 0 0 0Β-Pinene 0 0 0Eucalyptole 0 0 0Myrcene 0 0 0α-Phelandrene 0 0 03-δ-Carene 0 0 0Fenchone + Linalool 0 0 0Limonene 0 0 0Car<strong>vo</strong>ne 0 0 0Bornyl Acetate 0 0 0Σ VOC 13.4 14.9 0Measuring accuracy was continuously evaluatedthanks of according to regulation diagrams ofTVOC and VOCs for which are set limits in theStandard 6/2003 (tab. 1).DISCUSIONAs we can see in Table 5, the gypsum plasterboardswhich are made from inorganic and porous materialdo not emit VOCs in to the tested indoor air.Analysis of furniture brought quite similar results.There were not found any high VOCs concentrations(table 6).The biggest source of VOC emissions in newlyequipped room was the PVC flooring glued by therubber solvent glue. Values of TVOC were 3 hoursafter floor covering 27 times higher then WHO recommendedlimits. The highest values reached toluenewhich was 3 hours after floor gluing 10 timeshigher than limits and three days later still 3 timeshigher than limits.All values of VOC and TVOC were below thelimits in 28 days after finishing the room. Figure 2shows that there is a very strong dependency of theamount of emissions on time.CONCLUSIONOur research proved that the biggest sourceof VOC emissions was PVC flooring glued by therubber solvent glue.Equipment of the newly built room with theglued flooring emitted amounts of VOCs higherthan are the limits not only after 3 hours but alsoafter 72 hours. These results signify that roomswith newly glued floor covering are at least for 250hours not convenient for living.All other equipments in the room did not havetoo much high level of emissions.At this work we proved that there is dependencybetween TVOC values and values of chemicalsfrom the standard 6/2003.AcknowledgementThis work came out from the results of researchplan MSM 6215648902 financed by the Ministryof Education Youth and Sports.REFERENCES1. www.epa.gov/iaq/<strong>vo</strong>c.html2. http://www.epa.gov/iaq/pubs/BRI.html3. Vyhláška MZČR č.6/2003

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!