Protective Wiring of Relay Contacts<br />

Relay contacts are subject to electrical erosion. Especially with<br />

inductive and capacitive loads, the service life of the contacts will be<br />

reduced. For suppression of sparks and arcing, components such as RC<br />

combinations, nonlinear resistors, series resistors and diodes should<br />

be used.<br />

1 2<br />

3<br />

34<br />

1<br />

3<br />

2<br />

Typical AC applications<br />

with inductive load<br />

1) Load<br />

2) RC combination,<br />

e.g. RIFA PMR 209<br />

Typical RC combinations for<br />

230 V AC:<br />

capacitor 0.1 µF / 630 V,<br />

resistor 100 Ω / 1 W<br />

3) Contact