Product Specification<br />
Physical<br />
Wall Mount<br />
Outside dimensions<br />
Weight<br />
Enclosure material/description<br />
9.25 x 7.24 x 4.72 inch<br />
(235 x 184 x 120 mm)<br />
Nominal 2.2 lbs (1kg)<br />
Polycarbonate, flame resistant to<br />
<strong>UL</strong>94-5V<br />
Cable entry detail 10 cable entry knock outs, 1 x M16,<br />
5 x M20 underside, 4 x 18mm dia<br />
(PG11) at rear<br />
Transducer cable extensions<br />
Maximum separation<br />
Environmental<br />
Mounting<br />
Relative Humidity (IP Rating)<br />
Altitude<br />
Max. & min. temperature (electronics)<br />
Flammable atmosphere approval<br />
Approvals<br />
<strong>UL</strong><br />
CE approval<br />
Performance<br />
Accuracy<br />
Resolution<br />
Max. range<br />
Min. range<br />
Rate response<br />
Echo Processing<br />
Description<br />
3-conductor 20AWG screened<br />
3,280 ft (1000 metres) for greater<br />
separation distances please consult<br />
Pulsar<br />
Indoor/Outdoor<br />
IP65 (NEMA 4X) when closed, IP20<br />
when open<br />
2000m maximum<br />
-4 o F to 120 o F (-20 ºC to +50 ºC)<br />
Safe area: compatible with approved<br />
dB transducers (see transducer spec'<br />
sheet)<br />
Certificate Number E257330<br />
See EC Declaration of Conformity<br />
0.1% of the measured range<br />
(dB3 and external temperature<br />
compensation)<br />
0.02" (0.5mm) (dB3 and external<br />
temperature compensation)<br />
Dependant on application and<br />
transducer (maximum 49.213 ft (15m)<br />
dB40)<br />
Dependent upon application and<br />
transducer (minimum zero dB Mach3)<br />
fully adjustable<br />
DATEM (Digital Adaptive Tracking of<br />
Echo Movement)<br />