FlowCERT (UL)
UL manual - Pulsar Process Measurement
UL manual - Pulsar Process Measurement
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
U-Throated Flume<br />
ABSOLUTE<br />
If the flow calculation is to be absolute P702 = 1 the flow will be calculated<br />
using the formula: q = (2/3) 1.5 g n 0.5 C u C v C d bh 1.5<br />
Where: q = flowrate<br />
g n = gravitational acceleration (nominal value = 980.66 cm/s 2 ) h<br />
= head C u =<br />
shape coefficient calculated by <strong>FlowCERT</strong> LITE P724<br />
C v = velocity coefficient calculated by <strong>FlowCERT</strong> LITE P721<br />
C d = discharge coeffecient calculated by <strong>FlowCERT</strong> LITE P722<br />
b = throat width P711<br />
RATIOMETRIC<br />
U-Throated Flume<br />
If the flow calculation is to be ratiometric P702 = 2 the flow will be<br />
calculated using the formula:<br />
q= q cal (C v /C vcal )(C d /C dcal )(C u /C ucal )(h/h cal ) 1.5<br />
Where: q = flowrate<br />
q cal = flowrate at maximum head P705<br />
Cv = velocity coefficient calculated by <strong>FlowCERT</strong> LITE P721<br />
Cv cal = velocity coefficient at maximum head<br />
Cd = discharge coeffecient calculated by <strong>FlowCERT</strong> LITE P722<br />
Cd cal = discharge coefficient at maximum head<br />
Cu = shape coefficient P724<br />
Cu cal = shape coefficient at maximum head<br />
h = head<br />
= maximum head P704<br />
h cal<br />
Page 46