Daylight Saving Time<br />
Important Information<br />
In order to ensure the correct operation of Daylight Saving Time P932 Time<br />
should be checked, and adjusted if necessary, to ensure that it is set for the<br />
current valid time..<br />
P970 DST Enable<br />
When Enabled (set to 1) the internal clock will be automatically adjusted to<br />
compensate for the difference between standard time and Daylight Saving<br />
Time. Default = 1 (On)<br />
P971 DST Difference<br />
This parameter sets the time difference between standard time and Daylight<br />
Saving Time. The time difference is entered in HH:MM. Default = 01:00<br />
P972 DST Start Time<br />
This parameter is used to set the time of day at which Daylight Saving<br />
Time will start, the time is entered in the format HH: MM (24-hour<br />
format). Default = 02:00<br />
P973 Start Day<br />
Use this parameter to enter the day of the week (P974) that Daylight<br />
Saving Time is to start.<br />
Option<br />
Description<br />
2= Monday DST will start on a Monday<br />
3= Tuesday DST will start on a Tuesday<br />
4= Wednesday DST will start on a Wednesday<br />
5= Thursday DST will start on a Thursday<br />
6= Friday DST will start on a Friday<br />
7= Saturday DST will start on a Saturday<br />
8= Sunday (Default) DST will start on a Sunday<br />