3) Auxiliary Display, scrolling twelve digit display.<br />

Run Mode, displays measurement units (P104), status messages on<br />

signal and transducer, detail of Hot Key function selected. It can be also<br />

programmed to provide notification messages on alarms and pumps etc.<br />

for full details please refer to Display Parameters in the relevant<br />

parameter listing.<br />

Program Mode, displays Menu and Sub Menu headings, parameter<br />

details and options.<br />

4) Communicator status enunciator displays the current status of remote<br />

PC connection.<br />

5) Bargraph, display, gives visual indication of measurement in % of span.<br />

6) Level indicators<br />

Run Mode, indicates in which direction the level is moving.<br />

Program Mode, indicates at which level of the menu system you are at.<br />

There are two main operating modes for your <strong>FlowCERT</strong> LITE, Run Mode<br />

and Program Mode. There is also a Test Mode, used for checking the setup.<br />

All modes are now described.<br />

Run Mode<br />

This mode is used once the <strong>FlowCERT</strong> LITE has been set up in program<br />

mode. It is also the default mode that the unit reverts to when it resumes<br />

operation after a power failure.<br />

When <strong>FlowCERT</strong> LITE is switched on for the first time, it will display, in<br />

inches, the distance from the transducer face to the target. All relays by<br />

default are switched off.<br />

After programming is complete, any relays that are set will operate when the<br />

level reaches the relevant setpoint, and the LED’s will change colour (unless<br />

specifically switched off).<br />

Program Mode<br />

This mode is used to set up the <strong>FlowCERT</strong> LITE or change information<br />

already set. You must use the built-in keypad (standard) or alternatively the<br />

unit can be set up with a PC via the RS 232 Serial Interface (optional).<br />

Entering a value for each of the parameters that are relevant to your<br />

application provides all the programming information.<br />