Applications<br />
• Municipal Water and Sewage Treatment<br />
• Industrial Waste Water Treatment and Neutralization<br />
• Plating<br />
• Food and Beverage Processing and Manufacturing<br />
• Pulp and Paper<br />
• Chemical Manufacturing<br />
• Automotive Manufacturing<br />
60 SERIES HOT TAP PH /ORP SENSORS<br />
The 60 series Variable Insertion (Hot Tap) Differential pH and ORP Sensors have a<br />
built-in pre-amplifi er which allows the 60 series probes to transmit a signal up to 3000<br />
feet eliminating the need for the added expense of an amplifi er. They have replaceable<br />
salt bridges which increase the life and value of the sensor. They come complete with a<br />
standard 15ft cable but can be supplied with a cable of virtually any length. The cable is<br />
available in 5 wire or with a two wire 4-20 mA output built-in. Due to the quality of this<br />
product, the manufacturer offers a 30 month warranty.<br />
Features<br />
• Accurate differential measurement<br />
• Transmits up to 3000 ft (900 m)<br />
• Replaceable salt bridge<br />
• Flow thru or submersible<br />
• Temperature sensing device in all sensors<br />
• 1-1/4” NPT CPVC compression fi tting<br />
• Semi fl ushed face<br />
Parameter<br />
Enhanced<br />
Part # Measured Electronics Body Type<br />
Electrode Options<br />
P-60C-6 pH Standard 5 wire sensor Standard, 7/8" to 5" variable insertion None<br />
P-60C-7 pH Standard 5 wire sensor Hot Tap, Extended Length, 7/8" to 14" variable insertion None<br />
P-65C-6 pH Two wire transmitter, 4-20mA output Standard, 7/8" to 5" variable insertion None<br />
P-65C-7 pH Two wire transmitter, 4-20mA output Hot Tap, Extended Length, 7/8" to 14" variable insertion None<br />
P-60C-6-H pH Standard 5 wire sensor Standard, 7/8" to 5" variable insertion Hardened glass<br />
P-60C-7-H pH Standard 5 wire sensor Hot Tap, Extended Length, 7/8" to 14" variable insertion Hardened glass<br />
P-65C-6-H pH Two wire transmitter, 4-20mA output Standard, 7/8" to 5" variable insertion Hardened glass<br />
P-65C-7-H pH Two wire transmitter, 4-20mA output Hot Tap, Extended Length, 7/8" to 14" variable insertion Hardened glass<br />
R-60C-6 ORP Standard 5 wire sensor Standard, 7/8" to 5" variable insertion None<br />
R-60C-7 ORP Standard 5 wire sensor Hot Tap, Extended Length, 7/8" to 14" variable insertion None<br />
R-65C-6 ORP Two wire transmitter, 4-20mA output Standard, 7/8" to 5" variable insertion None<br />
R-65C-7 ORP Two wire transmitter, 4-20mA output Hot Tap, Extended Length, 7/8" to 14" variable insertion None<br />
R-60C-6-H ORP Standard 5 wire sensor Standard, 7/8" to 5" variable insertion Hardened glass<br />
R-60C-7-H ORP Standard 5 wire sensor Hot Tap, Extended Length, 7/8" to 14" variable insertion Hardened glass<br />
R-65C-6-H ORP Two wire transmitter, 4-20mA output Standard, 7/8" to 5" variable insertion Hardened glass<br />
R-65C-7-H ORP Two wire transmitter, 4-20mA output Hot Tap, Extended Length, 7/8" to 14" variable insertion Hardened glass<br />
Notes:<br />
• Standard cable length is 15 ft (5m) . For other lengths, please specify.<br />
• Flat faced glass electrodes are available for pH sensor only, add an F to the end of the part number.<br />
• Gold electrode are available for ORP sensor only, add a “G” to the end of the part number.<br />
• Also available with HTC hot tap assembly which contains a true union ball valve, add an “HTC” to the end of the part number.<br />