5<br />

5-6<br />

MS SERIES CONDUCTIVITY SENSORS<br />

• Epoxy body<br />

• Fits 3/4” installations<br />

• Graphite electrodes<br />

• Flow thru or submersible<br />

• Automatic temperature compensation<br />

• Variable insertion<br />

• 1 year limited warranty<br />

• Available in cell constant of 0.01(resistivity), 0.05. 0.1, 0.5, 1, 10, 20 and 50<br />

• Available with mounting options of low temperature (3/4” MNPT CPVC compression<br />

fi tting), high temperature (3/4” MNPT SS compression fi tting), and extended length cell<br />

for use with hot tap ball valve MS-HTC, and extended cable length<br />

• Available with GLI Temperature compensation device, PT1000 RTD or AquaMetrix<br />

temperature compensation device, 3KΩ thermistor<br />

• Available with a variety of accessories, contact customer service for more information.<br />

ES SERIES CONDUCTIVITY SENSORS<br />

• Electrodeless Conductivity Sensors<br />

• Polypropylene body<br />

• Convertible style fi tting<br />

• Temperature compensation: PT1000 RTD<br />

• 20 ft (6.6 m) Cable<br />

• 1 year limited warranty<br />

• Used in processes where conventional contacting sensors may foul or corrode.<br />

• Each sensors can be mounted in fl ow through applications or submersion mounted in<br />

tanks or open vessels.<br />

8760CLP CHLORINE & PH ANALYZER<br />

• Unique, new galvanic chlorine sensor, no reagents required<br />

• Includes two separate loops: total free chlorine and pH<br />

• Two chlorine readouts: total free chlorine and free available chlorine<br />

• Displays ppm chlorine, pH, temperature, alarm setpoints, and calibration status<br />

• Durable NEMA 4X (IP65) enclosure , two 4-20 mA outputs, two 10 amp SPDT relays<br />

• This is ideal for samples with fl uctuating pH values<br />

• Temperature compensation is obtained via a temperature sensor in the chlorine sensor.<br />

• Uses a unique galvanic sensor with a replaceable membrane cartridge that measures<br />

• Total Free Available Chlorine and Free Available Chlorine.<br />

• Temperature compensation is automatic or manual. The advantage of the galvanic cell<br />

is that an absolute zero measurement can be obtained<br />

• The 8760CLP analyzer has two isolated and assignable 4-20mA outputs, two 10Amp<br />

SPDT relays, and an RS485 port.<br />

• Pre-mounted on a panel for ease of installation.<br />

• Replacement membranes, pH probes and chlorine sensors are also available.