MS SERIES CONDUCTIVITY SENSORS<br />
• Epoxy body<br />
• Fits 3/4” installations<br />
• Graphite electrodes<br />
• Flow thru or submersible<br />
• Automatic temperature compensation<br />
• Variable insertion<br />
• 1 year limited warranty<br />
• Available in cell constant of 0.01(resistivity), 0.05. 0.1, 0.5, 1, 10, 20 and 50<br />
• Available with mounting options of low temperature (3/4” MNPT CPVC compression<br />
fi tting), high temperature (3/4” MNPT SS compression fi tting), and extended length cell<br />
for use with hot tap ball valve MS-HTC, and extended cable length<br />
• Available with GLI Temperature compensation device, PT1000 RTD or AquaMetrix<br />
temperature compensation device, 3KΩ thermistor<br />
• Available with a variety of accessories, contact customer service for more information.<br />
ES SERIES CONDUCTIVITY SENSORS<br />
• Electrodeless Conductivity Sensors<br />
• Polypropylene body<br />
• Convertible style fi tting<br />
• Temperature compensation: PT1000 RTD<br />
• 20 ft (6.6 m) Cable<br />
• 1 year limited warranty<br />
• Used in processes where conventional contacting sensors may foul or corrode.<br />
• Each sensors can be mounted in fl ow through applications or submersion mounted in<br />
tanks or open vessels.<br />
8760CLP CHLORINE & PH ANALYZER<br />
• Unique, new galvanic chlorine sensor, no reagents required<br />
• Includes two separate loops: total free chlorine and pH<br />
• Two chlorine readouts: total free chlorine and free available chlorine<br />
• Displays ppm chlorine, pH, temperature, alarm setpoints, and calibration status<br />
• Durable NEMA 4X (IP65) enclosure , two 4-20 mA outputs, two 10 amp SPDT relays<br />
• This is ideal for samples with fl uctuating pH values<br />
• Temperature compensation is obtained via a temperature sensor in the chlorine sensor.<br />
• Uses a unique galvanic sensor with a replaceable membrane cartridge that measures<br />
• Total Free Available Chlorine and Free Available Chlorine.<br />
• Temperature compensation is automatic or manual. The advantage of the galvanic cell<br />
is that an absolute zero measurement can be obtained<br />
• The 8760CLP analyzer has two isolated and assignable 4-20mA outputs, two 10Amp<br />
SPDT relays, and an RS485 port.<br />
• Pre-mounted on a panel for ease of installation.<br />