9<br />

9-18<br />

HF THERMOPLASTIC CENTRIFUGAL FANS<br />

<strong>Fabco</strong>’s HF thermoplastic radial fans are designed specifi cally for exhausting aggressive,<br />

low-aerosol gases, explosive atmosphere and ultra-clean air. The HF fan is<br />

resistant to attack from most chemicals and as such ideally suited for applications in<br />

chemical, pulp and paper, mining, plating, anodizing, fertilizer, pharmaceutical, waste<br />

water treatment facilities as well as educational and institutional labs. HF radial fans<br />

will accommodate explosive atmospheres. Our product range includes more than<br />

150 standard components which allows for the design and construction of numerous<br />

versions of fans. Axial, radial, and radial roof fans are available with direct drive motors<br />

for consistent and maintenance-free performance. The housing is fabricated from<br />

rotationally moulded Polyethylene (PE’s) that is both fl ame retardant and UV inhibited.<br />

Additional thermoplastic materials are available to suit most applications. A condensate<br />

drain is provided at the bottom point of the fan housing. The housing is mounted within<br />

a rigid hot dipped galvanized frame. All sizes are available in clockwise or counter<br />

clockwise rotations as well as six standard discharge positions. Both inlet and outlet<br />

diameters are the same sizes for ease of installation of adjacent duct work. In addition,<br />

fans can be fi tted with optional inlet and outlet fl anges. The impeller is manufactured<br />

of injection moulded fl ame retardant polypropylene (PPs), statically and dynamically<br />

balanced and keyed to the motor shaft by means of a taper lock bushing. The impeller<br />

can be removed without fi rst having to dismantle the housing. All fans are supplied<br />

with high effi ciency TEFC direct drive motors. Explosion and mill & chemical<br />

service rated motors are available upon request. Available accessories include vibration<br />

isolators, fl exible vibration isolators, inlet/outlet fl anges, shaft seals, inspection<br />

ports, weather covers, starter/disconnect switches, variable frequency drives. Fans are<br />

available in sizes ranging from 6” to 20” diameter with a variety of motors up to 3600<br />

rpm and 1/2 hp. These fans can accommodate fl ow rates of up to 88,000 cfm and static<br />

pressure up to 12” W.G.<br />

Benefi ts<br />

• Fan sizes from 6” up to 20” can attain a maximum effi ciency of 81% at the operating point.<br />

• Impellers are backward inclined providing the highest and quietest operation with non-overloading horsepower characteristic.<br />

• HF series impellers are 20% larger than the former Oktavent models; providing higher air and pressure specifi cations.<br />

• The rotationally moulded housing has greater structural integrity, impact strength, fl ame retardant and UV inhibited.<br />

• Available in axial as well.<br />

• Impeller has massive blades, which are not easily damaged should unforeseen objects enter the intake duct.<br />

Construction Features<br />

• Standard housing/impellers is made of premium quality fl ame retardant and UV inhibited polyethylene (PEs). PEs (polyethylene<br />

fl ame retardant gas temperature range is -20°C up to 60°C. Housings are rotationally moulded with a condensate drain at its<br />

lowest point.<br />

• The fan housing exhaust outlet can be rotated in steps of 45° through 360°. Normal position is 360°.<br />

• All thermoplastic impellers are injection moulded, statically and dynamically balanced.<br />

• The impeller is a self-cleaning, backward curved radial tip design allowing for stability at high S.P. and at low to medium fl ow rates.<br />

• Metal hub, shaft and stainless steel fasteners are encapsulated in plastic.<br />

• All belt drives shall have both shaft and belt guards attached which conforms to OSHA standard.<br />

• Inlet and outlet openings are the same diameter allowing for easy duct connections both to plastic and steel ducting.<br />

• Base frame is constructed of welded steel, and hot dip galvanized with motor support plate.<br />

• The impeller is secured directly on the motor shaft by means of a taper lock bushing, which allows the impeller to be removed<br />

without fi rst having to dismantle the housing.<br />

• All bearings are designed for a minimum L-10 life when rated at the fan’s maximum cataloged operating speed.<br />

• Only premium high effi ciency TEFC motors, which conform to IEC/Nema standards, are used. Special motors are available on<br />

request. Both the shaft and all supplementary hardware (nuts, bolts and washers) are 316 stainless steel.<br />

• Air performance ratings are based on tests and procedures performed in accordance with AMCA publication 211.