Appendix (Continued)<br />

Polymer Column Mobile phase Comments<br />

Polyacrylamide Controlledporosity<br />

glass<br />

Mean pore diameter:<br />

3125, 2000, 973,<br />

493, 240, <strong>and</strong> 123 A ˚<br />

Column size ¼<br />

4ft 3/8inID<br />

Polyacrylamide<br />

Acrylamide/<br />

sodium<br />

acrylate<br />

copolymer<br />

Dextrans,<br />

polystyrene<br />

sulfonated<br />

Polyacrylamide<br />

Polyethylene<br />

oxide<br />

Polyvinyl<br />

alcohol<br />

Hydroxyethyl<br />

cellulose<br />

Hydrolysed<br />

polyacrylamide,<br />

26/74<br />

mole %<br />

Acrylate/<br />

acrylamide<br />

copolymer<br />

Cellulose<br />

acetategrafted<br />

acrylamide<br />

copolymer<br />

© 2004 by Marcel Dekker, Inc.<br />

Controlledporosity<br />

glass<br />

Mean pore diameter:<br />

16.4–300 nm<br />

Column size:<br />

620 mm long<br />

7mmID<br />

Polyvinylpyrrolidone<br />

(PVP)-coated<br />

silica<br />

Mean pore diameter:<br />

100, 500, 1000,<br />

<strong>and</strong> 4000 A˚ Column size:<br />

30 cm length<br />

48 mm ID<br />

Wet-packed<br />

Sephacryl<br />

S 1000 superfine<br />

(Pharmacia Fine<br />

Chemicals)<br />

Column size:<br />

2.6 cm diameter<br />

70 cm or 100 cm<br />

bed height<br />

CPG-10<br />

Mean pore diameter:<br />

2023, 1223, 723,<br />

129 A ˚<br />

Column size:<br />

90 cm 9mmID<br />

Aqueous<br />

solution with<br />

0.005 M KCl<br />

Aqueous<br />

solution<br />

with<br />

0.1 M<br />

Na2SO4,<br />

which<br />

contained<br />

10 ppm<br />

biocide<br />

Kathon WT<br />

Chapter/<br />

reference<br />

RI detector 34<br />

RI detector<br />

Cubic<br />

B-spline<br />

calibration<br />

technique<br />

Water RI detector<br />

Universal<br />

calibration<br />

Aqueous<br />

solution<br />

with<br />

1 M NaCl<br />

Collected<br />

fractions<br />

<strong>and</strong> analysed<br />

by LALLS.<br />

Determined<br />

diffusion coefficients<br />

by photon<br />

correlation<br />

light<br />

scattering<br />

Water RI <strong>and</strong> UV<br />

detectors<br />

35<br />

36<br />

39<br />

37

Hooray! Your file is uploaded and ready to be published.