Table 7 SEC Conditions for Characterization <strong>of</strong> Ionic Cellulose Ethers<br />

Celluose<br />

derivative<br />

Packing<br />

material<br />

CMC Separon HEMA<br />

mono<br />

C60, G65<br />

or<br />

Mobile<br />

phase Detectors<br />

0.1 M or 0.1 mM<br />

NH 4NO 3<br />

DRI/<br />

Conductometry<br />

Flow<br />

rate<br />

(mL/min) Reference<br />

— 153<br />

Shodex OH pak DRI/DV/<br />

B804, B805 0.1 M NH4NO3 MALLS<br />

CMC TSK 0.1 M <strong>and</strong> 0.5 M MALLS/DRI — 155<br />

DS 0.71–2.95 30, 40, 50, 60 NaNO3 with 0.02% NaN3 CMC Separon HEMA 0.5 M NaOH or UV/RI 0.5 154<br />

1000<br />

0.4 M acetate<br />

buffer<br />

CMC TSK PW 0.02 M or MALLS/DRI 0.95 156<br />

DS 0.75–1.25 G6000, G5000, 0.1 M<br />

G3000<br />

NaNO3<br />

CMC TSK PWXL 0.1 M NaNO3 with MALLS/DRI — 157<br />

CMC<br />

30–60<br />

Analytical:<br />

0.02% NaN3 LS<br />

a<br />

TSK PWXL 0.1 M NaNO3 b /DV/RI 0.4 158–160<br />

G5000, G4000,<br />

G3000<br />

Preparative: 0.1 M Ammonium RI 1.1<br />

HiLoad 26/<br />

60 Superdex<br />

75<br />

acetate<br />

CMC TSK PW 0.3 M NaCl/ DRI 0.5 161<br />

G6000,<br />

G3000<br />

0.03 M Na2HPO4 CMC Sepharose 0.08 M –1.0M c<br />

— 0.4 140,142<br />

<strong>and</strong><br />

CM-DEAE<br />

cellulose<br />

CL-2B NaCl<br />

a Guard column G2500.<br />

b Two-angle LS.<br />

c Concentration range used at pH 2.5, 6, or 12.<br />

procedure can be used to determine the Mw <strong>of</strong> CMC. The neutral polymer dextran<br />

is commonly used for universal calibration <strong>of</strong> the SEC system. It has been proven<br />

valid for alkaline (0.5 M NaOH) <strong>and</strong> acid (0.4 M acetate buffer, pH 5) conditions<br />

(154). However, the authors recommended the alkaline eluent for MMD<br />

characterizations, due to the lower hydrodynamic volume <strong>of</strong> the CMC <strong>and</strong> to the<br />

lack <strong>of</strong> aggregation as compared to the acetate buffer system.<br />

© 2004 by Marcel Dekker, Inc.