Table 2 Characteristics <strong>of</strong> Agarose <strong>and</strong> Agarose/Acrylamide Mixed Resins for Protein<br />

SEC<br />

Support name <strong>and</strong><br />

manufacturer Vmax a<br />

Selectivity b<br />

pH<br />

Stability<br />

Particle size<br />

(m)<br />

<strong>Exclusion</strong><br />

limit (kDt)<br />

Sepharose wc<br />

6B 30 10–4000 4–9 45–165<br />

4B 26 60–20,000 4–9 45–165<br />

2B<br />

Sepharose<br />

15 70–40,000 4–9 60–200<br />

wc CL<br />

6B 30 10–4000 3–14 45–165<br />

4B 26 60–20,000 3–14 45–165<br />

2B 15 70–40,000 3–14 60–200<br />

Superose c 12 Prep Grade 30 1–300 1–14 20–40<br />

Superose c 6 Prep Grade<br />

Ultrogel<br />

30 5–5000 1–14 20–40<br />

d<br />

AcA202 1–15 3–10 60–140 22<br />

AcA54 5–70 3–10 60–140 90<br />

AcA44 10–130 3–10 60–140 200<br />

AcA34<br />

Bio-Gel<br />

20–350 3–10 60–140 750<br />

e<br />

A-0.5m 20 1–500 4–13 40–80<br />

A-1.5m 20 1–1500 4–13 80–150<br />

A-5m 20 10–500 4–13 150–300<br />

A-15m 20 40–15,000 4–13<br />

A-50m 15 100–50,000 4–13<br />

a<br />

Maximal linear velocity (cm/hr) for columns in the 1–6cm diameter range.<br />

b<br />

Selectivity is defined as the fractionation range for globular protein in Daltons.<br />

c<br />

Amersham Biosciences Corp., 800 Centennial Ave., P.O. Box 1327, Piscataway, New Jersey 08855-<br />

1327.<br />

d<br />

Ciphergen Biosystems, Inc., 6611 Dumbarton Circle, Fremont, California 94555.<br />

e<br />

Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Herules, California 94547.<br />

6.3 Selection <strong>of</strong> Hardware<br />

Once the most productive resin has been identified, an appropriately configured<br />

column must be selected. Information about the required throughput, sample<br />

volume, chemical resistance, <strong>and</strong> cycle time must be included in choice <strong>of</strong><br />

column(s). Conventional preparative <strong>and</strong> process SEC columns (packed or empty)<br />

are available from Amicon/Wright (Danvers, MA), Pharmacia Biotechnology<br />

(Lund, Sweden), TosoHaas (Philadelphia, PA), <strong>and</strong> Millipore/Waters (Milford,<br />

MA). The Pharmacia Process Stack TM Column PS 370 is the most noteworthy<br />

© 2004 by Marcel Dekker, Inc.