Table 1 Errors (in %) Characteristics <strong>of</strong> Good <strong>and</strong> Poor<br />

<strong>Chromatography</strong><br />

Angles Molar mass Radius<br />

Good chromatography<br />

Many 0.07 0.6<br />

Low þ 908 þ High 0.2 2<br />

Very low þ 908 0.6 10<br />

Poor chromatography<br />

Many 0.5 3.0<br />

Low þ 908 þ High 1 5<br />

Very low þ 908 14 80<br />

<strong>of</strong> good <strong>and</strong> poor chromatography. Naturally, single 908 detectors cannot be<br />

expected to yield any reliable results for molecules whose size may be measured<br />

from MALS.<br />

7 COPOLYMERS<br />

Copolymers may be formed <strong>of</strong> monomers A <strong>and</strong> B in a r<strong>and</strong>om manner, that is,<br />

<strong>of</strong> a structure such as AABABBABABAABBABA, or with monomer blocks<br />

such as AAA <strong>and</strong> BBB to form a block copolymer such as AAABBBBBBAA-<br />

ABBBAAAAAA, <strong>and</strong> so on. These copolymers, in turn, may be homogeneous<br />

(that is, with relative contribution <strong>of</strong> each homopolymer independent <strong>of</strong> molar<br />

mass) or heterogeneous (that is, with varying relative compositions that vary<br />

with molar mass). Since each homopolymer has its corresponding dn/dc, it<br />

becomes very difficult to characterize the scattered light from chromatically<br />

separated species <strong>of</strong> such copolymers in terms <strong>of</strong> a specific molar mass at each<br />

elution. However, if the copolymer is homogeneous, we may then take a<br />

weighted average <strong>of</strong> the two dn/dc values dnA=dc <strong>and</strong> dnB=dc. Heterogeneous<br />

copolymers present a challenge for MALS because there are many combinations<br />

that could produce copolymers having identical hydrodynamic sizes, that is, that<br />

therefore would co-elute if separated by SEC columns, for example. For such<br />

separations, each slice would be expected to contain a variety <strong>of</strong> molecular<br />

structures <strong>and</strong> molar masses.<br />

The reader should be aware that the light scattering characteristics <strong>of</strong><br />

polymers (<strong>and</strong> copolymers) are assumed to be described by the Rayleigh–<br />

Gans–Debye (RGD) approximation discussed, for example, in Refs 5 <strong>and</strong> 14. In<br />

this approximation, each constituent <strong>of</strong> a molecule scatters light independently<br />

© 2004 by Marcel Dekker, Inc.