Appendix (Continued)<br />

Polymer Column Mobile phase Comments<br />

Dextran- Porous glass<br />

grafted Mean pore diameter:<br />

acrylamide 3000, 1400, 700,<br />

copolymer 350, 240, 170 A˚ Column size:<br />

60 0.762 cm ID<br />

Polyacrylamide<br />

CPG-10<br />

2000 A˚ Bio glass 2500 A˚ ,<br />

125/240/370 A˚ Porasil DN<br />

400/800 A˚ Porasil CX<br />

200/400 A˚ Polyacrylamide Dry-packed<br />

controlled<br />

porosity glass<br />

Mean pore diameter:<br />

700, 1000, <strong>and</strong><br />

3000 A˚ Particle size:<br />

200/400 mesh<br />

Column size:<br />

3.8 in. ID<br />

4–6.5 ft long<br />

Polyacrylamide<br />

hydrolysed<br />

polyacrylamide<br />

Acrylamide/<br />

acrylic acid<br />

copolymers<br />

Polyacrylamide<br />

Acrylamide/<br />

dimethyl<br />

diallylammonium<br />

chloride<br />

copolymers<br />

TSK columns:<br />

Guard þ<br />

G6000 PWXL þ<br />

G5000 PWXL þ<br />

G4000 PWXL þ<br />

G3000 PWXL<br />

TSK columns:<br />

Guard þ<br />

G6000 PW þ<br />

G5000 PW þ<br />

G3000 PW<br />

Polyacrylamide Shodex<br />

OH-Pak<br />

or<br />

Ultrahydrogel<br />

© 2004 by Marcel Dekker, Inc.<br />

Aqueous<br />

solution<br />

with 0.05 M<br />

potassium<br />

biphthalate<br />

Chapter/<br />

reference<br />

RI detector 38<br />

Water RI detector 41<br />

Aqueous<br />

solution<br />

with 0.2 M<br />

Na2SO4 þ<br />

1g/25 L<br />

Tergital<br />

NPX (Union<br />

Carbide<br />

Corp.)<br />

Aqueous<br />

solution<br />

with 0.3 M<br />

NaCl þ 0.1 M<br />

KH2PO4<br />

adjusted<br />

pH ¼ 7.0 by<br />

50/50 w/w<br />

NaOH<br />

Aqueous<br />

solution<br />

with 0.3 M<br />

Na2SO4 þ<br />

1% acetic<br />

acid<br />

pH ¼ 3.1<br />

Pure water or<br />

0.5 M LiNO3<br />

aqueous<br />

solution<br />

DRI/LALLS<br />

dual<br />

detectors<br />

RI/LALLS<br />

dual<br />

detectors<br />

RI/LALLS<br />

dual<br />

detectors<br />

LALLS/<br />

Viscometer/<br />

RI triple<br />

detectors<br />

47<br />

44<br />

44<br />

46