An error message is issued when the PLB changes this transfer qualifier from the time a request to<br />

transfer is made until the addressed slave asserts its Sln_addrAck, or the transfer is terminated<br />

through Mn_abort or PLB_MnRearbitrate or Timeout.<br />

• Error 2.28.2<br />

An error message is issued if this transfer qualifier does not match Mn_lockError when<br />

PLB_MnAddrAck is active.<br />

8.8.7 PLB_A<strong>Bus</strong>/PLB_UAbus<br />

The following error messages are issued for this signal:<br />

• Error 2.29.1<br />

An error message is issued when the PLB changes this transfer qualifier from the time a request to<br />

transfer is made until the addressed slave asserts its Sln_addrAck, or the transfer is terminated<br />

through Mn_abort or PLB_MnRearbitrate or timeout.<br />

• Error 2.29.2<br />

An error message is issued if this transfer qualifier does not match Mn_A<strong>Bus</strong> when<br />

PLB_MnAddrAck is active.<br />

• Error 2.29.3<br />

An error message is issued when the PLB_Abus word address is non-zero during a line write<br />

transfer.<br />

8.8.8 PLB_busLock<br />

The following error messages are issued for this signal:<br />

• Error 2.30.1<br />

An error message is issued if this arbitration qualifier does not match Mn_busLock when<br />

PLB_MnAddrAck is active.<br />

• Error 2.30.2<br />

An error message is issued if PLB_busLock and PLB_SAValid are active at the same time and the<br />

bus is not actually locked. This may be due to the previous request being aborted.<br />

• Error 2.30.3<br />

An error message is issued when PLB_busLock is active and SYS_plbReset is active.<br />

• Error 2.30.4<br />

An error message is issued if this arbitration qualifier does not match Mn_busLock when the bus is<br />

already locked.<br />

• Error 2.30.5<br />

An error message is issued if this signal is asserted with no PLB_PAValid or PLB_SAValid and the<br />

bus is not locked.<br />