Chapter —Program Instructions<br />

SYSVAR, cont.<br />

20. Direct or transfer mode (Read only)<br />

SYSVAR(20) allows you to read if the printer is set up for direct thermal<br />

printing or thermal transfer printing, which is decided by your choice of<br />

paper type in the printer’s setup.<br />

The printer returns:<br />

0 = Direct thermal printing<br />

1 = Thermal transfer printing<br />

21. Printhead density (Read only)<br />

SYSVAR(21) allows you to read the density of the printer’s printhead,<br />

expressed as number of dots per millimeter.<br />

22. Number of dots (Read only)<br />

SYSVAR(22) allows you to read the number of dots in the printer’s printhead.<br />

23. Transfer ribbon sensor (Read only)<br />

SYSVAR(23) allows you to read the status of the transfer ribbon sensor in<br />

thermal transfer printers.<br />

The printer returns:<br />

0 = No ribbon detected<br />

1 = Ribbon detected<br />

24. Power up since last SYSVAR(24) (Read only)<br />

This system variable is important when using the <strong>Intermec</strong> Direct Protocol.<br />

At power up, all data not saved as programs, files, fonts or images will<br />

be deleted, and most instructions will be reset to their respective default<br />

values. SYSVAR(24) allows the host to poll the printer to see if a power up<br />

has occurred, for example because of a power failure and, if so, download<br />

new data and new instructions.<br />

The printer returns:<br />

0 = No power up since last SYSVAR(24)<br />

1 = Power up has occurred since last SYSVAR(24)<br />

25. Obsolete<br />

26: Ribbon low condition (Read only)<br />

This parameter allows you to read the status of the ribbon low sensor, assuming<br />

that the printer is fitted with a thermal transfer mechanism. In the<br />

Setup Mode (Media/Paper Type/Transfer/Low Diameter), you can specify<br />

a diameter in mm of the ribbon supply roll, when SYSVAR(26) will switch<br />

from 0 to 1.<br />

The printer returns:<br />

0 = Ribbon not low<br />

1 = Ribbon low<br />