Chapter —Character Sets and Fonts<br />

Character Sets<br />

The following information applies to all single-byte character sets:<br />

• Characters between ASCII 00 decimal and ASCII 31 decimal are<br />

unprintable control characters as listed below.<br />

• Characters between ASCII 32 decimal and ASCII 127 decimal can<br />

always be printed, regardless of 7-bit or 8-bit communication protocol,<br />

provided that the selected font contains the characters in question.<br />

• Characters between ASCII 128 decimal and ASCII 255 decimal can<br />

only be printed if the selected font contains the characters in question<br />

and an 8-bit communication protocol is used. If you use 7-bit communication,<br />

select another national character set (see NASC statement) or<br />

use a MAP statement to remap a character set.<br />

• If a character, which does not exist in the selected font, is used, an error<br />

condition will occur.<br />

Non-printable control characters (ASCII 00-31 dec)<br />

ASCII Character Meaning<br />

00 NUL Null<br />

01 SOH Start of heading<br />

02 STX Start of text<br />

03 ETX End of text<br />

04 EOT End of transmission<br />

05 ENQ Enquiry<br />

06 ACK Acknowledge<br />

07 BEL Bell<br />

08 BS Backspace<br />

09 HT Horizontal tabulation<br />

10 LF Line feed<br />

11 VT Vertical tabulation<br />

12 FF Form feed<br />

13 CR Carriage Return<br />

14 SO Shift out<br />

15 SI Shift in<br />

16 DLE Data link escape<br />

17 DC1 Device control one<br />

18 DC2 Device control two<br />

19 DC3 Device control three<br />

20 DC4 Device control four<br />

21 NAK Negative acknowledge<br />

22 SYN Syncronous idle<br />

23 ETB End of transmission block<br />

24 CAN Cancel<br />

25 EM End of medium<br />

26 SUB Substitute<br />

27 ESC Escape<br />

28 FS File separator<br />

29 GS Group separator<br />

30 RS Record separator<br />

31 US Unit separator<br />