Chapter —Bar Codes<br />

UPC-E Composite with CC-A or CC-B<br />

Separate Instructions<br />

BARTYPE: "UPCE_CC"<br />

BARRATIO: Not applicable.<br />

BARMAG: Specifies the x-dimension width in dots of the most narrow element for<br />

both the linear bar code and the 2D code. Default: 2. Maximum: 8.<br />

BARHEIGHT: Specifies the height of the linear bar code. Default: 100.<br />

BARFONT ON/<br />

OFF:<br />

BARSET Instruction<br />

ON: The human readable for the linear bar will be printed under the linear<br />

bar code.<br />

If BARSET is set to 1, the human readable for the 2D bar code is<br />

printed too.<br />

OFF: No human readable is printed.<br />

BARSET Instruction<br />

[#] Optionally specifies the start parameter<br />

Bar code type "UPCE_CC"<br />

1 Placeholder Value insignificant. 0 is not allowed.<br />

2 Placeholder Value insignificant. 0 is not allowed.<br />

3 Barmag/Enlargement See BARMAG.<br />

4 Barheight See BARHEIGHT.<br />

5 Placeholder Value insignificant.<br />

Character exclusion in bar code (does not<br />

affect human readables)<br />

Always 1 (default). The bar code and the<br />

human readable field will include exactly<br />

the same data.<br />

7 Height of separator pattern row in dots Value must be 1-2 × BARMAG. For<br />

example, if BARMAG = 5, 5-10 is OK<br />

8 Height of each row in 2D bar code in dots Default: 0 (= 3 × BARMAG)<br />

9 Separator character between data to linear<br />

bar code and 2D bar code<br />

ASCII 2-255 dec. Default: ASCII 124<br />

dec. ASCII 48-57 dec. not allowed.<br />

10 2D human readables On/Off 0 = No human readable 2D field.<br />

1 = Print human readable 2D field.<br />

Input Data<br />

No. of characters: 6<br />

Check digit: 1 Added automatically.<br />

Digits: 0-9<br />

Uppercase letters: No<br />

Lowercase letters: No<br />

Punctuation marks: No<br />

Start characters: No<br />

Stop characters: No<br />

8 <strong>Intermec</strong> Fingerprint <strong>v8.70.0</strong>/v10.0.0 Programmer´s <strong>Reference</strong> <strong>Manual</strong>