Chapter —Bar Codes<br />

EAN.UCC 128 Composite with CC-C<br />

Separate Instructions<br />

BARTYPE: "EAN128_CCC"<br />

BARRATIO: Not applicable.<br />

BARMAG: Specifies the x-dimension width in dots of the most narrow element for<br />

both the linear bar code and the 2D code. Default: 2.<br />

BARHEIGHT: Specifies the height of the linear bar code. Default: 100.<br />

BARFONT ON/<br />

OFF:<br />

BARSET Instruction<br />

ON: The human readable for the linear bar will be printed under the linear<br />

bar code.<br />

If BARSET is set to 1, the human readable for the 2D bar code is<br />

printed too.<br />

OFF: No human readable is printed.<br />

BARSET Instruction<br />

[#] Optionally specifies the start parameter<br />

Bar code type "EAN128_CCC"<br />

1 Placeholder Value insignificant. 0 is not allowed.<br />

2 Placeholder Value insignificant. 0 is not allowed.<br />

3 Barmag/Enlargement See BARMAG.<br />

4 Barheight See BARHEIGHT.<br />

5 Number of columns/row in 2D bar code 0 (default) = select the largest number<br />

of columns for the 2D code to fit within<br />

the linear bar code including its quiet<br />

zones.<br />

Character exclusion in bar code (does not<br />

affect human readables)<br />

0: The bar code will not include any<br />

of the characters space, (, ), and carriage<br />

return [CHR$(13)] but they will<br />

be printed in the human readable field.<br />

Carriage returns make it possible to print<br />

human readable in multiple rows.<br />

1 (default): The bar code and the human<br />

readable field will include exactly the<br />

same data.<br />

7 Height of separator pattern row in dots Value must be 1-2 × BARMAG. For<br />

example, if BARMAG = 5, 5-10 is OK<br />

8 Height of each row in 2D bar code in dots Default: 0 (= 3 × BARMAG)<br />

9 Separator character between data to linear<br />

bar code and 2D bar code<br />

ASCII 2-255 dec. Default: ASCII 124<br />

dec. ASCII 48-57 dec. not allowed.<br />

10 2D human readables On/Off 0 = No human readable 2D field.<br />

1 = Print human readable 2D field.<br />

8 <strong>Intermec</strong> Fingerprint <strong>v8.70.0</strong>/v10.0.0 Programmer´s <strong>Reference</strong> <strong>Manual</strong>