Chapter —Program Instructions<br />

SYSVAR, cont.<br />

31: Last control character sent (Read only)<br />

This parameter allows you to read the last control character sent from the<br />

MUSE protocol (special applications).<br />

The printer returns one of the following alternatives:<br />

NUL<br />

ACK<br />

NAK<br />

CAN<br />

32: Odometer value (Read only)<br />

Returns the length of media feed past the printhead (the PD41 odometer<br />

cannot distinguish printheads, so it counts length for the platform).<br />

Resolution: 10 meters.<br />

33: DSR condition on "uart1:" (Read only)<br />

This parameter allows you to read the DSR (Data Send Ready) condition<br />

on the serial channel "uart1:". Not available on the EasyCoder PD41.<br />

The printer returns:<br />

0 = No<br />

1 = Yes<br />

34: TrueType character positioning mode (Set or Read)<br />

This parameter allows you to select one of three modes for the positioning<br />

of TrueType characters and also to read for which mode the printer is set.<br />

The modes are:<br />

0 = Standard mode (default)<br />

This mode was introduced with <strong>Intermec</strong> Fingerprint 7.2.<br />

1 = Compatible mode<br />

This mode is compatible with <strong>Intermec</strong> Fingerprint 7.xx earlier than<br />

version 7.2.<br />

2 = Adjusted mode<br />

This mode was introduced with <strong>Intermec</strong> Fingerprint 7.2.<br />

35: Setup Saving (Set or Read)<br />

This parameter allows you to decide whether a change in the printer’s setup<br />

is to be saved as a file (that is be effective after a reboot or power down) or<br />

not be saved (volatile). You can also read for which alternative the printer is<br />

set. Note that the SYSVAR (35) setting at the moment when the new setup<br />

is entered decides whether it will be saved or not.<br />

The alternatives are:<br />

0 = Setup saved to file (non-volatile) Default<br />

1 = Setup not saved to file (volatile)<br />

<strong>Intermec</strong> Fingerprint <strong>v8.70.0</strong>/v10.0.0 Programmer´s <strong>Reference</strong> <strong>Manual</strong>