RH1<br />

HP T IP T LP T LP T<br />

DEA<br />

RH2 RH3 RH5 RH6 RH7 RH8<br />

5<br />

New LSTG<br />

HE4 (intercooler<br />

of CO2 compressor)<br />

30<br />

HE2<br />

HE1 ( Reboiler of<br />

MEA Stripper)<br />

Throttling one LP cylinder<br />

4<br />

COND<br />

HE3 (CO2 cooler<br />

of MEA Stripper)<br />

3 2<br />

Fig. 12. The structure of clutched LP turbine option<br />

4.4. Results analysis<br />

The performance analysis of three cases of this section is listed in Table 4, the three cases include:<br />

Case 3: based on Case 2, Add a new letdown steam turbine generator (LSTG), as discussed in<br />

Section 4.1;<br />

Case 4: based on Case 3, adopting thermal energy integration, as discussed in Section 4.2;<br />

Case 5: based on Case 4, Throttling one of LP cylinder, as discussed in Section 4.3;<br />

Table 4. Performance analysis of Case 3-5<br />

Base Case Case 3 Case 4 Case 5<br />

Coal input rate (kg/s) 46.66 46.66 46.66 46.66<br />

CO2 capture amount (kg/hr) - 447423 447423 447423<br />

CO2 capture rate (%) - 90 90 90<br />

Reboiler heat duty (MW) - 420.83 420.83 420.83<br />

CO2 compression work (MW) - 39.91 39.91 39.91<br />

Outlet pressure of LSTG (bar) - 3.0 3.0 3.0<br />

Extracted steam flow (kg steam/kg CO2) - <strong>1.</strong>553 <strong>1.</strong>553 <strong>1.</strong>553<br />

Heat recovery from CO2 capture(MW) - 0 73.05 73.05<br />

Power output of steam turbine (MW) 604 450.18 459.9 474.23<br />

Power output of LSTG (MW) - 43.69 44.59 44.59<br />

gross power output (MW) 493.87 504.49 518.82<br />

Auxiliary work (MW) 30.22 85.51 85.51 85.51<br />

Net power output 573.8 408.36 418.97 433.31<br />

Net efficiency of plant (%) 40.28 28.67 29.41 30.42<br />

Efficiency penalty (%-points) - 1<strong>1.</strong>61 10.87 9.86<br />

As is shown in Table 4, compared with Case 2, when a new letdown steam turbine generator was<br />

added, the net efficiency of Case 3 can be increased by 2.27%-points, rising from 26.40% to