DES-3526 / DES-3526DC Fast Ethernet Layer 2 Switch<br />

To view the Received Error Packets Table, click the link View Table, which will show the following<br />

table:<br />

The following fields can be set:<br />

Parameter Description<br />

Figure 8- 10. Rx Error Analysis window (table)<br />

Time Interval Select the desired setting between 1s and 60s, where "s" stands for seconds. The<br />

default value is one second.<br />

Record Number Select number of times the Switch will be polled between 20 and 200. The default<br />

value is 20.<br />

Crc Error Counts otherwise valid packets that did not end on a byte (octet) boundary.<br />

Under Size The number of packets detected that are less than the minimum permitted packets<br />

size of 64 bytes and have a good CRC. Undersize packets usually indicate collision<br />

fragments, a normal network occurrence.<br />

Over Size Counts packets received that were longer than 1518 octets, or if a VLAN frame is<br />

1522 octets, and less than the MAX_PKT_LEN. Internally, MAX_PKT_LEN is equal to<br />

1522.<br />

Fragment The number of packets less than 64 bytes with either bad framing or an invalid CRC.<br />

These are normally the result of collisions.<br />

Jabber The number of packets with lengths more than the MAX_PKT_LEN bytes. Internally,<br />

MAX_PKT_LEN is equal to 1522.<br />

Drop The number of packets that are dropped by this port since the last Switch reboot.<br />

Show/Hide Check whether or not to display Crc Error, Under Size, Over Size, Fragment, Jabber,<br />

and Drop errors.<br />

Clear Clicking this button clears all statistics counters on this window.<br />