The user may set the following parameters:<br />

Parameter Description<br />

DES-3526 / DES-3526DC Fast Ethernet Layer 2 Switch<br />

From/To A consecutive group of ports may be configured starting with the selected port.<br />

Mode Active - Active LACP ports are capable of processing and sending LACP control<br />

frames. This allows LACP compliant devices to negotiate the aggregated link so the<br />

group may be changed dynamically as needs require. In order to utilize the ability to<br />

change an aggregated port group, that is, to add or subtract ports from the group, at<br />

least one of the participating devices must designate LACP ports as active. Both<br />

devices must support LACP.<br />

Passive - LACP ports that are designated as passive cannot initially send LACP<br />

control frames. In order to allow the linked port group to negotiate adjustments and<br />

make changes dynamically, one end of the connection must have "active" LACP<br />

ports (see above).<br />

After setting the previous parameters, click Apply to allow your changes to be implemented. The<br />

LACP Port Table shows which ports are active and/or passive.<br />

MAC Notification<br />

MAC Notification is used to monitor MAC addresses learned and entered into the forwarding<br />

database.<br />

MAC Notification Global Settings<br />

To globally set MAC notification on the Switch, open the following window by opening the MAC<br />

Notification folder and clicking the MAC Notification Global Settings link:<br />

The following parameters may be modified:<br />

Parameter Description<br />

Figure 6- 12. MAC Notification Global Settings window<br />

State Enable or disable MAC notification globally on the Switch<br />

Interval (sec) The time in seconds between notifications.<br />

History size The maximum number of entries listed in the history log used for notification. Up to<br />

500 entries can be specified.<br />