Parameter Description<br />

DES-3526 / DES-3526DC Fast Ethernet Layer 2 Switch<br />

Configuration Name A previously configured name set on the Switch to uniquely identify the MSTI (Multiple<br />

Spanning Tree Instance). If a configuration name is not set, this field will show the<br />

MAC address to the device running MSTP. This field can be set in the STP Bridge<br />

Global Settings window.<br />

Revision Level This value, along with the Configuration Name will identify the MSTP region configured<br />

on the Switch. This field can also be set in the STP Bridge Global Settings<br />

window.<br />

MSTI ID This field shows the MSTI IDs currently set on the Switch. This field will always have<br />

the CIST MSTI, which may be configured but not deleted. Clicking the hyperlinked<br />

name will open a new window for configuring parameters associated with that<br />

particular MSTI.<br />

VID List This field displays the VLAN IDs associated with the specific MSTI.<br />

Clicking the Add button will reveal the following window to configure:<br />

Figure 6- 22. Instance ID Settings window – Add<br />

The user may configure the following parameters to create a MSTI in the Switch.<br />

Parameter Description<br />

MSTI ID Enter a number between 1 and 15 to set a new MSTI on the Switch.<br />

Type Create is selected to create a new MSTI. No other choices are available for this field<br />

when creating a new MSTI.<br />

VID List (1-4094) This field is used to specify the VID range from configured VLANs set on the Switch.<br />

Supported VIDs on the Switch range from ID number 1 to 4094.<br />

Priority (0-61440) Select a value between 0 and 61440 to specify the priority for a specified MSTI for<br />

forwarding packets. The lower the value, the higher the priority. This entry must be<br />

divisible by 4094.<br />

Click Apply to implement changes made.<br />

To configure the settings for the CIST, click on its hyperlinked name in the Current MST Configuration<br />

Identification window, which will reveal the following window to configure:<br />