Updating the <strong>InterScan</strong> <strong>Gateway</strong> <strong>Security</strong> <strong>Appliance</strong> Firmware<br />

9. Click OK to start the device image update. The AFFU begins uploading the new<br />

device image to the appliance, and the AFFU DOM screen displays the progress<br />

of the update.<br />

FIGURE 15-28. AFFU DOM screen showing progress of the update<br />

When the update is complete, the AFFU displays a message stating that the<br />

device image uploaded successfully.<br />

FIGURE 15-29. AFFU “flash DOM successfully uploaded” message<br />

Troubleshooting Device Image Upload with Option 5<br />

If you are unable to upload the appliance device image in rescue mode using option 5,<br />

verify the following:<br />

• Make sure that the Ethernet cable is connected to the appliance management port.<br />

(See Figure 15-20, “The appliance back panel showing location of management<br />

port,” on page 22.)<br />

• Make sure that the uploading client is in IP range 192.168.252.x / 255.255.255.0.<br />

You can use the ping command to check the appliance connection.<br />

• Make sure that the appliance is still in rescue mode. You can verify that by<br />

viewing the Preconfiguration rescue mode console. (See Putting the <strong>Appliance</strong><br />

into Rescue Mode on page 15-13.)<br />

15-27