Mount the Chemical Tank<br />
<strong>Installation</strong><br />
• Mount the chemical tank as close as possible to the injection pump. Minimize the length of the product line<br />
between the chemical tank and injection pump. Avoid any product lines longer than 5 ft. [1.5 m] between the<br />
chemical tank and injection pump inlet port.<br />
Note: Long product lines between the chemical tank and injection pump may cause high vacuum<br />
pressures on the pump inlet, long pump priming times or difficulty priming the pump, and larger<br />
amounts of chemical waist during rinsing.<br />
If vacuum errors are encountered during pump operation, one or both of the following corrective<br />
measures may be necessary to reduce inlet pressure:<br />
• Reduce the inlet plumbing length<br />
• Increase the tubing size<br />
• Mount the Sidekick Pro ISO pump so that the line between the injection pump and chemical supply tank is<br />
near level with a slight incline to help relieve air bubbles. The line connected to the pump inlet must not<br />
raise chemical above 2 ft. [0.6 m] from the chemical supply tank outlet. See Figure 9 on page 22.<br />
Mount the Sidekick Pro ISO Pump<br />
• Mount the Sidekick Pro ISO pump as close as possible to the selected point of injection.<br />
• Mount the Sidekick Pro ISO pump so that the outlet port is pointing up. The pump will not meter product<br />
application correctly if the pump is mounted in any other orientation.<br />
• The Sidekick Pro ISO should be mounted in a location which provides access to the pump and control node<br />
to simplify calibration and troubleshooting.<br />
<strong>Manual</strong> No. 016-0171-509 Rev. B 17<br />