Injection Pump Vacuum Switch<br />

To replace the vacuum switch (P/N 063-0171-035):<br />

Replacement Parts<br />

1. Disable and shutdown any automatic product control features of the Sidekick Pro ISO injection system and<br />

turn off the vehicle when replacing the vacuum switch assembly.<br />

2. Disconnect the vacuum switch connector from the motor control cabling. Be careful to keep dust, debris, or<br />

liquid chemicals which may seep from the injection pump head from contaminating the cable connections.<br />

3. Loosen the vacuum switch while securing the connected fitting to prevent damage to the pump head.<br />

4. Apply RectorSeal ® or equivalent thread sealant to the new vacuum switch and thread into the pump head.<br />

5. If necessary, slide the protective covering on the vacuum switch back slightly to expose the hex surface for<br />

tightening the vacuum switch body.<br />

6. Tighten the vacuum switch body two or three quarter turns to secure the vacuum switch.<br />

Note: Do not over tighten the pressure transducer. Overtightening the pressure transducer may<br />

damage the pump head.<br />

7. Be sure to replace the protective cover over the flow switch before operating the pump.<br />

Injection Pump Flow Monitor Sensor<br />

WARNING<br />

Always use caution when performing<br />

maintenance or servicing an injection pump or<br />

system which has been previously pressurized.<br />

Wear appropriate protective equipment to<br />

prevent contact with hazardous chemicals and<br />

rinse the chemical system as instructed by the<br />

chemical manufacturer prior to performing<br />

maintenance.<br />

WARNING<br />

Hazardous chemicals may be under pressure<br />

even if the pump has not been in service<br />

recently. Before replacing any components on<br />

the injection pump, thoroughly rinse the<br />

injection pump with clean water to remove<br />

excess chemical residue.<br />

Perform the following procedure to replace the flow monitor sensor (P/N 063-0173-492).<br />

<strong>Manual</strong> No. 016-0171-509 Rev. B 69<br />