Chapter 6<br />

4. Select the Tools icon from the soft keys area and select the diagnostics icon at the top of the display to<br />

access the Product Diagnostics screen for the selected product pump.<br />

Pump Status<br />

Run Time Data<br />

Pump Status<br />

The current pump mode is displayed for reference during diagnostic tests. When priming or calibrating the<br />

injection pump, verify that this status display reads “Cal/Prime” before priming or calibrating the injection pump.<br />

The following status modes may be displayed on the Product Diagnostics screen:<br />

Run Time Data<br />

Modes Description<br />

Auto (Automatic) This mode allows for the injection pump to run at a target application<br />

rate (oz./ac or L/ha) by compensating for changes in section width<br />

and speed.<br />

<strong>Manual</strong> This mode allows for the injection pump to be run at a fixed flow rate<br />

(oz./min. or L/min.). The application rate (oz./ac. or L/ha) does not<br />

compensate for section width and speed changes. This mode is<br />

typically used for testing purposes.<br />

Rx This mode allows the system to automatically change the rate of<br />

injected chemical based upon a prescription map loaded on the VT<br />

display.<br />

CAL/PRM<br />

(Calibrate/Prime)<br />

This mode allows for chemical to be primed to the outlet of the pump<br />

and to validate pump performance through a 1 oz. calibration test.<br />

The following information is available for the selected pump control channel.<br />

Note: The following usage statistics are the last available values recorded during pump operation.<br />

Pressure. The pressure of the injection product monitored at pump outlet port.<br />

FER Value. The FER (flow to encoder ratio) value is a tool used in conjunction with the FER Error Cal to<br />

identify the relative efficiency of the pump. This area displays a value between 0 and 100.<br />

Motor RPM. The current RPM of the injection pump motor is displayed in this area.<br />

52 Sidekick Pro ISO <strong>Installation</strong> & <strong>Operation</strong> <strong>Manual</strong>