Chapter 4<br />

1. Select the Tools icon from the soft keys area on the right side of the Product Control Home screen.<br />

2. Touch the Alarms icon along the top of the display to access the Alarms Setup screen.<br />

Refer to the following sections for details on the alarm settings available on the Alarms Setup screen.<br />

Low Tank<br />

Enter the volume at which the system will display an alert when the calculated volume of product remaining in<br />

the tank drops below the desired value. Enter a value of zero to disable the low tank alarm.<br />

Off Rate<br />

Enter the percent at which the off rate alarm will activate. The off rate alarm activates when the actual rate<br />

differs from the target rate by the programmed value for longer than five seconds.<br />

FER Cal<br />

The FER (Flow Encoder Ratio) cal value is used to set the flow error tolerance of chemical injection<br />

applications. Increase the FER error cal value to set a tighter tolerance. Set the FER error cal to zero to turn off<br />

all flow monitor alarms for the injected chemical. The default value is 8.<br />

38 Sidekick Pro ISO <strong>Installation</strong> & <strong>Operation</strong> <strong>Manual</strong>