Display Smoothing<br />

Calibration<br />

Toggle the display smoothing feature to smooth the rate displayed on the product control home screen. With<br />

the feature enabled, as long as the actual rate is within 10% of the actual application rate, the target rate will<br />

display as the actual rate on the display. The actual rate will be displayed if the actual rate does not reach the<br />

target rate dead band (+/-3%) within 10 seconds.<br />

Zero Speed Shutoff<br />

The zero speed feature will automatically turn off product application if the vehicle speed drops below 0.7 mph<br />

[1.1 km/h] while in automatic mode. To restart the system, cycle the master switch ‘Off’ then back ‘On.’ A speed<br />

of 0.7 mph [1.1 km/h] must be maintained for more than 10 seconds or the zero speed feature will reactivate.<br />

Agitator Enable<br />

If equipped with an injection system featuring an agitator enabled output, this option enables or disables a<br />

chemical agitator.<br />

Ratio Rate Enable<br />

The ratio rate feature configures the selected control channel to apply an injected chemical at a rate<br />

proportional to the carrier product flow rate. The ratio rate application mode must be enabled via the control<br />

console and a ratio rate cal value must be entered for each product controlled in ratio to the carrier.<br />

Note: If the off rate alarm is triggered frequently during injection applications in ratio rate mode, access<br />

the volume per minute display on the control console and verify that the target flow rate is within<br />

the application range for the pump.<br />

The ratio rate calibration value is entered as the ratio of injected chemical to carrier in ounces per gallon<br />

[deciliters per liter].<br />

Alarms Setup Screen Calibration Settings<br />

In addition to the product control capabilities of the Raven ISOBUS product control system, the ISOBUS<br />

communication protocol offers excellent error detection capabilities, making it very suitable and reliable for<br />

agricultural applications. To access the Alarm Setup screen:<br />